5.15.22 Output Apparent Wind Correction Status
#
##
#OC,15(CR)
This command will stop automatic output and reply with:
C,15,s(CR)
s = 0 for no corrections being applied to apparent wind
values.
1 for corrections being applied to apparent wind values for
use in further calculations.
5.15.23 Enable/Disable Apparent Wind Correction
#
##
#IC,15,s(CR)
s = 0 for no correction to be applied to apparent wind
values.
1 for correction to be applied to apparent wind values used
in further calculations.
5.15.24 Input Calibration Value
#
##
#IC,n,x...x(CR)
n = calibration number
x....x = calibration value
N Calibration Type Data Format Max Value
1 Boatspeed (port) x.xx 9.99
2 Boatspeed (stbd) x.xx 9.99
3 Windspeed Hz/kt x.xx 9.99
4 MHU Angle xxx.x 359.9
5 Leeway xx.x 99.9
6 True Wind Correction ignored
7 Zero Correction Angle ignored
8 Max Mast Twist ignored
9 Max Twist Angle ignored
10
Windspeed offset
x.xx 9.99
11 Depth datum m xx.x 99.9
12 Depth datum ft xx.x 99.9