Owner manual

HB-0844-04
5-24
Notes
1. When calibration value 1 is changed to select a desired input sensor, the
linear value is no longer updated and a constant value is displayed until the
page key is pressed.
2. Extra functions selected, and then removed, remain in the display menu
but with no data shown until the system is switched off and then back on
again.
3. Linear functions will always be shown if selected by CAL VAL 4 on linear
5. They will show no data if the CAL VAL 1 setting is configured to 1 or 2.
5.9.4 Expansion Processor Wiring
The Expansion Processor is connected to the system Fastnet for power and
data requirements.
TERMINAL FUNCTION WIRE COLOUR
1 Meter 5 SIN Green
2 Meter 5 COS Blue
3 Meter 6 SIN Red
4 Meter 6 COS Violet
5 Meter 7 SIN Red
6 Meter 7 COS Violet
7 Meter 8 SIN Green
8 Meter 8 COS Blue
9 Meter Lighting Yellow
10 Meter Common Orange
11 Meter Ground Black
12 N/C
13 N/C
14 Network Data -ve Green
15 Network Data +ve White
16 Network Screen Screen
17 Battery Supply
Ground
Black
18 Battery Supply 12V Red
19 Battery Volts Sense Link to 18
20 N/C
21 Ground Blue
22 Sensor Supply
+6.5V
Red