Owner manual
HB-0844-04
4-19
8-BUTTON FULL FUNCTION
DISPLAY WIRING DETAILS
FFD CABLE
FUNCTION
FFD CABLE
COLOUR
SYSTEM
NETWORK
REMOTE
BUTTON
Network Data -ve Green Green
Network Data +ve White White
Network Cable Shield Shield Shield
Ground Black Black Blue
Supply +ve Red Red
Remote Control Button Yellow Red
Not used Brown
INSTALLATION NOTES FOR HYDRA 2000
• The system requires at least one FFD.
• An FFD can be connected at any point on the system network.
• Multiple FFD's can be used on the system network. Each can control and enter data into the system
processor memory.
• FFD's can be used in combination with all other display types; that is NMEA FFD's, Halcyon displays,
20/20 and Pilot displays.
SCREENED CABLES
• Shielded cables are supplied to provide protection against unwanted emissions (EMC) and must be
connected in accordance with these instructions.
NETWORK TERMINATION
• If the FFD is the last unit on the system network a network terminator MUST be fitted across the network
data wires, that is between the green and white wires.