Owner manual

HB-0844-04
4-19
8-BUTTON FULL FUNCTION
DISPLAY WIRING DETAILS
FFD CABLE
FUNCTION
FFD CABLE
COLOUR
SYSTEM
NETWORK
REMOTE
BUTTON
Network Data -ve Green Green
Network Data +ve White White
Network Cable Shield Shield Shield
Ground Black Black Blue
Supply +ve Red Red
Remote Control Button Yellow Red
Not used Brown
INSTALLATION NOTES FOR HYDRA 2000
The system requires at least one FFD.
An FFD can be connected at any point on the system network.
Multiple FFD's can be used on the system network. Each can control and enter data into the system
processor memory.
FFD's can be used in combination with all other display types; that is NMEA FFD's, Halcyon displays,
20/20 and Pilot displays.
SCREENED CABLES
Shielded cables are supplied to provide protection against unwanted emissions (EMC) and must be
connected in accordance with these instructions.
NETWORK TERMINATION
If the FFD is the last unit on the system network a network terminator MUST be fitted across the network
data wires, that is between the green and white wires.