universal interface box installation IS-2509-02
CE Certification: This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference, the user is encouraged to try to correct the interference by relocating the equipment or connecting the equipment to a different circuit.
trademark All rights reserved. No part of this manual may be reproduced or transmitted in any form or by any means including photocopying and recording, without the express written permission of B&G. Information in this document is subject to change without notice. B&G reserves the right to change or improve its products and to make changes in the content without obligation to notify any person or organisation of such changes.
system connections connections 2 Fastnet Cable Fastnet Cable System components share data together via a common Fastnet databus and are supplied with bayonet connectors for ease of installation. A selection of cable lengths are available with options for straight and right angle connectors to suit most requirements.
supported NMEA sentences (v2.
supported NMEA sentences (v2.
selectable NMEA The Selectable NMEA feature allows control over which sentences are received and transmitted by the h1000 Universal Interface. This gives flexibility when interfacing to other manufacturers’ products such as radars and chart-plotters. Selectable NMEA allows you to filter out unwanted NMEA messages and prevents duplicated data on the system.
electrical connections external connections 2 3 Two Fastnet² connectors are provided on the top of the unit. These connectors allow connection to the rest of the system for the supply of power and data. 4 The table below shows pin functions.
electrical connections 1 NMEA TX- 2 Wire the cables into the interface box as shown in the diagram opposite. 3 NMEA method NMEA SCN 5 SCREEN 6 RED + 7 No CONN. 8 No CONN. 9 BLUE - UNIVERSAL NMEA RX+ 4 NMEA RX- 10 ALARM internal connections NMEA TX+ To open the connector, carefully push a small flat headed terminal screwdriver into the slot directly above the relevant terminal number. Push the bare end of the wire into the terminal connector and withdraw the screwdriver.
installation BGM014062 113.1mm 48mm 53mm Drill 4 off holes (2.9mmØ)for No.6 x 3/4" self tapping screws ORIENTATION BOX BASE OUTLINE WARNING: THIS DRAWING IS NOT TO SCALE Use the Installation instructions and the template provided with the unit packaging to install the Interface Box.