electrical connections
Use cable Part No. BGM-023005
With this connector
Power/Data
This is the main Power and Navigation NMEA
port. The CND receives data from the GPS
receiver and sends data to the instrument
system using this port. Sentences decoded:
DBT, DPT, GGA, GLL, GSA, GSV, HDG, HDM,
HDT, MWV, RMC, VHW, VTG, VWR, VWT,
WPL, ZDA and DTM (B&G special). Sentences
Transmitted: APA, APB, BOD, BWC, BWR,
DBT, GGA, GLL, HDG, HSC, RMA, RMB,
RMC, VTG, WCV, XTE, ZDA and ZTG.
Pin Colour Signal
Red 1 +12 Vdc
Black 0 Vdc /NMEA OUTPUT (GND)
Blue NMEA OUTPUT +
Green NMEA INPUT +
White UNUSED
Yellow NMEA INPUT –
Screen SCREEN
Use cable Part No. BGM-023006
With this connector
NMEA In (Instrument Interface)
Auxiliary NMEA input port for NMEA messages
transmitted by the instrument system.
Sentences decoded: DBT, DPT, HDG, HDM,
HDT, MWV, VHW, VWR, VWT and WPL.
Pin Colour Signal
RED 1
NMEA INPUT+
Blue
NMEA INPUT-
Green
SCREEN
5
2 3
41
Front view of
male connector pins
Fastnet
2
One FastNet² connector is provided at the rear
of the unit. For connection to the h1000
system.
Pin Number Signal
1
12V
2 Busy
3 FastNet²-
4 FastNet²+
5 0V