Table 4.4: SP-40 thru SP-65 Water Requirements
Water Flow Rate Minimum Supply Max Operating
Connection Size Line Pressure Max Temp (@45PSI/3Bar) Line Size Pressure
US Metric PSI Bar F C gal/min liter/min US Metric US Metric
3/4” DN 19 30-75 2-5 200 93 11 40 3/4 DN 19 125 PSI 8 Bar
Table 4.5: SP-100 thru SP-165 Water Requirements
Water Flow Rate Minimum Supply Max Operating
Connection Size Line Pressure Max Temp (@45PSI/3Bar) Line Size Pressure
US Metric PSI Bar F C gal/min liter/min US Metric US Metric
1” DN 25 30-75 2-5 200 93 30 113 1-1/4 DN 32 125 PSI 8 Bar
Table 4.6: SP-185 thru SP-195 Water Requirements
Water Flow Rate Minimum Supply Max Operating
Connection Size Line Pressure Max Temp (@45PSI/3Bar) Line Size Pressure
US Metric PSI Bar F C gal/min liter/min US Metric US Metric
1-1/4” DN 32 30-75 2-5 200 93 37 140 1-1/2 DN 38 125 PSI 8 Bar
Never touch internal or external steam pipes, connections, or components. These
surfaces can be extremely hot and will cause severe burns. The steam must be
turned off and the pipe, connections, and components allowed to cool before the
pipe can be touched.