9.4 Global Parameters
The following parameters apply globally for the machine. They are always used no matter which
program is currently chosen.
Table 9.6: Global Parameters
Number Description Units Standard value Set value
1 Preselected program number 100
2 Empty piles on program change 0/1 1
3 Reset counter when changing program 0/1 0
4 Total counter on start page 0/1 0
5 Correction piece length after TE stop mm -50
6 Adjust ski width not until LE PhC XF 1 0/1 0
7 Correct piece length Photo A 0-2 0
8 Minimal piece length mm 200
10 Duration stop stacker before flaps open ms 350
11 Duration stacker flaps open ms 250
12 Duration delay stacker flaps ms 0
15 Delay push out pile ms 500
16 Duration push out pile ms 1000
17 Delay belt after push out ms 0
20 Duration until jam Photocell dark ms 3000
22 Interval pulse blowing ms 80
23 Pulse duration ms 40
25 Number of pieces until jam LF 3
26 Number of pieces until jam XF 4
70 Delay deploy cylinders ms 300
80 Persist interval statistics s 600
81 Persist interval time statistics s 600
85 Piece length endurance run mm 1000
86 Cycle time endurance run ms 3500
90 Language 0-5 0
95 Duration until automatic switch-off s 300
98 Duration until pasknife reset s 3600
99 Current program number 0-99 0
9.5 Program Specific Parameters
The following parameters can be adjusted differently per program.
29