6.1 Default Values
Because the programmed language can vary, no default program names are set, except for program
100, which will be called Single cycle.
Table 6.1: M720 Factory Default Values
Parameter Description Value
1 Drying method TIME
3 Min. drying time 10 m
4 Max. drying time 45 m
5 Drying time 40 m
7 Dry temperature 167
o
F / 75
o
C
8 Offset sensor 2 2
o
F /
o
C
9 Offset infrared 4
o
F /
o
C
10 Humidity dry val. 15.00%
18 Cooldown time 10 m
19 Cooldown temp. 95
o
F / 35
o
C
23 Drum direction REV
24 Drum speed 100.00%
25 Drum stop time 1 s
26 Drum run time 45 s
29 Anti crease funct. YES
32 Max. temp. rise 0
o
/m
33 Max. temp. fall 0
o
/m
In the default programs, some parameter values are set to a different value to provide different
programs to start with. The following default programs are available: