Figure 4.2: IS Series - Heat Control Panel
1. Heating Control Panel
2. Speed Control Panel
3. Exhaust
4. Compression roll release
5. Front Return table
4.1.1 Heat Control Panel
Control Panel Detail – refer to Figure 4.2 on page 22:
IGNITION – Indicates a call for heat
GAS VALVE – Indicates the gas valve is open, and machine is heating.
FLAME SAFEGUARD Will briefly illuminate upon call for heat. Continuous illumination indicates
ignition failure.
TEMPERATURE CONTROL Sets operating point of machine. Press the up arrow to increase the
operating temperature and the down arrow to decrease the operating temperature.
ALARM HIGH LIMIT Safety thermostat has been activated. Check for proper operation of tem-
perature control.