Instruction Manual
Installation
HP-60 Technical Specifications
15
MODEL
DOOR OPENING AND HEIGHT:
Diameter mm in 450 17.7
Height of door bottom above floor mm in 569 22.4
DRIVE INFORMATION:
Number of motors
Size of motor kW Hp 3.7 5
WATER INLETS and CONSUMPTION:
Hot water size DN in 20 3/4
Cold water size DN in 20 3/4
Additional water Inlet DN in 20 3/4
Average HOT water consumption/ cycle liters gal 223 59
Average COLD water consumption/cycle liters gal 106 28
DRAIN OUTLETS AND CAPACITY:
Number of drains standard
Number of drains optional (water re-use)
Drain size mm in 76.2 3
Drain capacity liter/min gpm 246 65
STEAM INLET and CONSUMPTION:
Steam inlet size DN in 13 1/2
Required steam to heat bath 10F (5.55C)LOW kg lbs 8.4 3.8
Required steam to heat bath 10F (5.55C)HIGH kg lbs 9.2 4.2
Average Steam consumption per cycle kg BHP 35 2.2
1
Number 1
Number 1
Units
HP-60
Number