User guide

23
Installation
Steam Connection
Never touch internal or external steam pipes, connections, or
components. These surfaces can be extremely hot and will cause severe
burns. The steam must be turned off and the pipe, connections, and
components allowed to cool before the pipe can be touched
For machines equipped with optional steam
heat, install piping in accordance with
approved commercial steam practices.
Steam requirements are shown in the table
below. Failure to install the supplied steam
filter may void the warranty.
MODEL
STEAM INLET and CONSUMPTION:
Steam inlet size DN in 20 3/4
Required steam to heat bath 10F (5.55C)LOW kg lbs 3.15 7
Required steam to heat bath 10F (5.55C)HIGH kg lbs 4.77 10.5
Average Steam consumption per cycle kg lbs 72 158
MODEL
STEAM INLET and CONSUMPTION:
Steam inlet size DN in 20 3/4
Required steam to heat bath 10F (5.55C)LOW kg lbs 3.8 8.4
Required steam to heat bath 10F (5.55C)HIGH kg lbs 5.8 12.76
Average Steam consumption per cycle kg lbs 88 194
Units HI-85
HI-125Units