User guide
18
Installation
HI-125 HI-85
Mounting Bolt Installation
The HI Series uses 5/8-11 x 8” bolts.
Embed the bolts in 3500 psi reinforced
concrete with a minimum of 12” thickness.
The threaded end of the bolt should extend
2 inches from the surface of the floor. As an
option, a welded bolt locating fixture is
available (rebar frame). This rigid welded
assembly is made of reinforcing rod (rebar)
and is designed to be encased in concrete.
Machine Foundation
Dynamic Frequency
kN lbs kN/m2 lbs-ft2 kN lbs kN/m2 lbs-ft2
HI-85 7.56 1700 5.01 104.64 17.39 3910 11.52 240.6
HI-125 19.53 4390 10.64 222.22 25.58 5750 13.93 290.93
Hz
9.65
8
Static floor load Static pressure Dynamic floor load Dynamic pressure
6.1
155
6.1
155
15.75
400
15.75
400
4
101
4
101
15.2
386
3X
1
25
61.4
1560
51.6
1310