Manual

ExampleHeatCycle
Anycyclecanbeconvertedtoaheatingcyclebyinsertinga
stepafterthefill,andsettingtheendstepconditiontoa
temperature(SeeStep2below).
Step1-Filltoawaterlevelwithhotwater.Heatison,and
willengagewhenaminimumwaterlevelismet.Watchdog
timerof9:00allowstimetofillbeforeanalarmisgenerated.
Step1endswhenthewaterlevelisreached.
Step2-Heatoutputison.Watchdogtimerof30:00allows
timetoheattotherequiredtemperaturebeforeanalarmis
generated.Step3endswhenthetargettemperatureis
reached.
Step3-Heatoutputison,Chemical2outputison,Relay
12ison.Step3endswhenatimeof1:00elapses.
Step4-Topoffstep,sameoutputsasstep1.
Step5-Heatoutputisoninordertoregulatetemperature
duringtheagitationphase.Step5andtheentirecycleis
completewhenatimeof7:00elapses.
Function12345
CoolDown
BalLoad
Drain
ColdWater
HotWaterYesYes
HeatingYesYesYesYesYes
C9090909090
Chem1
Chem2Yes
Chem3
Chem4
HardWater(Chem5)
Relay16
Relay11(AuxFill)
Relay12(InjectionFlush)Yes
Relay13(Balancing)
Motor11111
SpeedRPM4242424242
Relay17(Chem6)
Relay18(Chem7)
Relay19(Chem8)
Relay20(AuxDrain)
Relay21
Relay22(Buzzer)
Relay23(ColdSpray)
Relay24(HotSpray)
Levelcm2424
TempC90
WDTm:s9:0030:005:00
Timem:s1:007:00
EndStep
Step
EL6StandardPrograms,17-April-2007