Owner's manual

Customizingtheindividualprograms
Thepasswordrequiredtoaccessthisphaseis955.Proceedasfollows:presskeysUPand1at
thesametime.AtthispointthemessagePASSWOappearsonthedisplay,thenpressENTER.
Thedisplaynowshows00000.PressthreetimestheDOWNkeytoerasethreezeroesstarting
fromtheright,thentypeinthepassword955.PressENTER.Actualprogrammingstartsnow.
DISPLAY VALUESALLOWED DESCRIPTION
ProgramselectionsthroughtheUPandDOWNkeys.Thevariousconfiguredprogramsaredisplayed.
SelectthedesiredonebypressingENTER.
LANGUAGE 0..7 Language:
0English
1Italian
2French
3German
4Spanish
NAME 12alphanumeric
characters
Enteranewprogramname
Thisnameisdisplayedwhenaprogramisselectedby
pressinganumerickey,orwhenthemachineturnson
againafterapowerfailureoccurredduringprogram
execution.PresstheDOWNkeytoerasetheexisting
text.
CYCLETIME 0..max.valuesetinhigh
levelprogramming
Cycletime.
Thisfielddeterminesthedurationofthedryingprogram.
Thevalueisexpressedinminutes.
TROTATION 10..max.valuesetinhigh
levelprogramming
Rotationtime(onlyifreversingisenabled)
Timeinsecondsthebasketmoves(bothdirections).
TPAUS min.valuesetinhighlevel
programming...250
Rotationpausetime(onlyifreversingisenabled)
Timeinsecondsthebasketstopsbetweenforwardand
reverse.
°HEATING 30°C...max.valuesetin
highlevelprogramming
Heatingtemperature
Temperaturetobemaintainedinsidethebasketduringthe
dryingphase.In°Cor°F,dependingonthevalueentered
infieldCELSNintheoperatingranges.
COOLTIME 0..max.valuesetinhigh
levelprogramming
Cooldowntime.
Duration(inminutes)ofthecoolingdownphaseatthe
endofdrying.
°COOLING 20°C..max.valuesetin
highlevelprogramming
Cooldowntemperature
Temperatureatwhichthecoolingdownphaseendsafter
thedryingphase.
Thevaluecanbein°Cor°F,dependingonthevalue
enteredinfieldCELSNinhighlevelprogramming
BUZZER 0..15(sec) Buzzertime.
Duration(inseconds)oftheacousticsignalthatindicates
programcompletion(endofthecoolingdownphase)
Programming
9