Owner's manual

5.Motorbackward
6.Blower
Turnsontheexhaustblower.
Innon-reversingmodels,thiscontrolsboththe
blowerandthecylindermotors.
7.Heating
Onwhenthecylindertemperatureisbelowthe
programmedsetpoint.
8.RFU
NotusedintheUSA.
Thekeyboardisequippedwiththefollowingkeys
0-9:thesekeyshaveadifferentfunction
dependingonthesituation.
1.Ifyouarechoosingaprogramtorun,
eachkeycorrespondstoaprogram-pressinga
keywilldisplaythenameoftheassociated
programifnamed(Sheets,Towels,etc.).
2.Ifyouareenteringnumericalvalues,each
keyinputstheassociatednumber.
1.Ifyouareenteringaprogramname
(thereforeanalphanumericsequence),pressing
eachkeywillresultintheinputtingofthe
associatedvalues(numbersorletters)inturn.
Forexample,ifyouwanttoenterA,press
button0twice,ifyouwanttoenterZ,push
button7fivetimes.
Afterpressingbutton7fivetimes,ifyoupressit
oncemoreanother7willbegenerated.Ifyou
pressitfortheeighthtime,aWisgenerated
andsoon,inrotationforalltheotherkeysas
well.
“START:startstheselectedprogram
(bothincaseofsinglecycleorpre-setprograms)
orrestartstheprogrampreviouslyinterrupted
(throughSTOPorbyopeningthedoor).
“STOP:thiskeyalsocarriesoutdifferent
functionsifpressedunderdifferentoperating
conditions:
1.Duringprogramexecution,pressingthis
buttononcesuspendstheprogram(withthe
possibilityofrestartingitfromwhereitleftoff),
whilepressingittwicestopstheprogramforgood
;
Keyboard
Commandsreversedirectionofthecylinder
motor(reversingmodelsonly).
2.Duringprogramming,thisbuttonallows
toexitthecurrentlyprogrammeditemand
returnstotheprogramselectionmode.Alldata
entereduptothatpointwillbestored;
3.Silencesthebuzzer.
SINGLECYCLE:ifpressedwhilethe
dryeriswaitingforaprogramtobeselected,
allowstosetasimplifiedprograminwhichthe
operatorcanchoosebothtemperatureand
programlength.PleaseseeSection5.2-Single
Cycle.
UPandDOWN:thesekeysare
usedduringthevariousconfigurationphases
forthefollowingpurposes:
1.Toselectthetypeofcurrencyduringthe
machinesconfigurationphase(incaseofcoin
boxoperation);
2.Toselecttheprogramtomodifyduring
theprogrammodificationphase;
3.TosetYES/Novalueswhere
configurationrequiresuchachoice:for
example,whenyou’resettingupcoinbox
operation,pressUPforYESandpressDOWN
forNO;
4.Wheninputtingaprogramnameor
number,pressingDOWNalonewillallowyou
toerasethecharactersorthenumbers
displayedatthefarright.
UPand1:pressthesetwokeys
simultaneouslywhilethedryeriswaitingfor
programselectiontoaccessthepassword
mode.Inotherwords,theboardwaitsfora
numericpassword,andoncethisischangedit
willbepossibletoaccessthevariousmachine
andprogramconfigurationphases.
ENTER:belowisalistofwhatcan
happenwhenthisbuttonispressedwiththe
controlunitoperatingunderdifferentmodes:
1.Afterselectingaprogram(withoutthe
coinbox),pressingthiskeywillstartthesame
program.Ifthisdoesnotoccur,itmaybethat
oneoftheconditionssuppliedbytheinputsis
missing.Incaseofcoinboxoperation,pressing
thisbuttonstartsthemachineonlyafter
reachingtheminimumstartingcreditrequired
fortheselectedprogram;
2.Aftersuspendingprogramexecution(by
Introduction