Owner's manual
Introduction
Description
Mainfunctionalfeatures
I/Osignalstoandfromthedryer
TheEDGisequippedwiththefollowing
features:
Six-digitalphanumericdisplaywithhigh
brightness(messageslongerthan6digitsscroll
acrossthescreen)
Keyboardwith16keys
Buzzerforacousticsignaling
8opto-isolateddigitalinputs(on/off)
6digitalrelayoutputs
1probefortemperaturemeasure
Datastorageincaseofpowerfailure
Throughthevariousmenus,whichcanbe
accessedbytypinginthecorrectpassword,the
usercanchoosefromthefollowingoptions:
Operatorinterfacelanguage
Operationwithtemperaturein°Cor°F
Reverseenable/disable
Coinenable/disable.
Inaddition,itispossibletonameprogramsso
theycangiveinformationonthetypeoffabric
theprogramisconfiguredfor(Sheets,Towels,
etc).
Fordetailsonconfigurationoptionspleaseturn
toProgramming.
TheEDGisequippedwithasetofdigitalinputs
andoutputswhosefunctionislistedbelow.
1.Dooropen
Aprogramwillnotstartifthedoorisopen
duringstartup.
Ifthedoorisaccidentallyopenedwhilea
programisrunning,theprogramwillstopand
thedisplaywillindicateadiagnosticmessage.
Theprogramrestartsoncethedoorisclosed
andstartispressed.
2.Filterdooropen
>
>
>
>
>
>
>
Inputs
Aprogramwillnotstartifthelintdoor/draweris
openduringstartup.
Ifthelintdoor/drawerisaccidentallyopened
whileaprogramisrunning,theprogramwill
stopandthedisplaywillindicateadiagnostic
message.
Theprogramrestartsoncethedoorisclosed
andstartispressed.
3.DepressionAlarm
Theprogramwillnotstartwhenthepressure
alarmisactive.TheEDGusesthecabinetsail
switchtodetermineiftheexhaustbloweris
operational.Thesailswitchmustbeopenfora
programtostart,andthenbepulledclosedby
airflowfortheprogramtocontinue.Forthis
reason,stopsandstartstooclosetogetherin
timemaynotworkbecauseoffaninertia.Ifa
programstartsandsailswitchremainsopen,an
alarmisgeneratedandthebuzzersounds(see
chapter“Alarms”.
4.Motoroverload
Ifthemotorsoverload(s)tripduringprogram
execution,theprogramwillstop,generatingan
alarmwithrelevantdiagnosticonthedisplay
andthebuzzerwillsound.
5.Coinbox1
Inthecoinboxversion,thissignalindicatesthat
atype1coinhasbeendeposited(whosevalue
isconfiguredinthespecificfield).NotUsed.
6.Coinbox2
Inthecoinboxversion,thissignalindicatesthat
atype2coinhasbeendeposited(whosevalue
isconfiguredinthespecificfield).NotUsed.
1.Gascontrolunitreset
NotUsedintheUSA.
2.Cycleunderway
Indicatesthatadryingcycleiscurrentlyunder
way.Thissignalremainsevenwhenthe
programisinterrupted(throughthekeyboard
orbyopeningthedoor).
3.BlowerAutoclean
Eachtimeaprogramstarts,compressedair
cleanstheblower,preventinglintbuildup.
4.Motorforward
Commandsforwarddirectionofthecylinder
motor(reversingmodelsonly).
Outputs
4