8-39
Program Drying time Drying temperature
1 40 167 °F / 75 °C
2 30 140 °F / 60 °C
3 30 113 °F / 45 °C
4 40 140 °F / 60 °C
5 25 122 °F / 50 °C
6 25 113 °F / 45 °C
7 25 104 °F / 40 °C
8 20 104 °F / 40 °C
9 0 n/a (only cool down)
10 50 194 °F / 90 °C
50 20 140 °F / 60 °C
8.2 Default machine parameter settings
The default machine parameter settings are:
01 Tmp in Fahrenheit NO
05 Maintenance cycl 0
06 Finished beeptim. 5 s
07 Overview status 0
11 RS485 stationnr. 1
12 RS485 baudrate 0
16 Cnt.reset no pass YES
26 Rotation time-out 10 s
27 Jog drum speed 25 %
30 Heater reset time 3 s
31 Blower clean time 5 s
32 Blower WYE del. 10 s
33 Del. check airflow 10 s
40 Max. inlet temp. 302 °F / 150 °C
9. Installing and setting up a controller
Installation of the basic controller kit is described in 9.1 below. The information given is
based on the controller only. It is important to review the documentation for the machine in which
the controller will be installed to ensure correct connection and use of the controller, and testing
procedures.
Optional kits are available to expand the capabilities of the controller. These are:
Infra-red sensor (9.2) for more accurate measurement of garment temperature.
Humidity sensor (9.3) for more accurate determination of linen dryness.
2
nd
NTC (temperature) sensor (9.4) for inlet temperature limiting and hence linen protection.
I/O expansion board (9.5) for providing additional input and output connections if required.
Please note that the infra-red and humidity sensors have an expansion board as part of the
kit. The DQ 01 controller has one connector for and expansion board so either the infra-red or the
humidity sensor can be fitted, not b oth. The 2
nd
temperature sensor can always be fitted.