Datasheet

DATA SHEET
Technical changes reserved
Digital Temperature value
Measuring range –50 .. +150 °C / -58 ..+302 °F
Temp (°C) Temp (°F) Tsic 206 / 306
(digital)
-50 -58 0x000
-10 14 0x199
0 32 0x200
25 77 0x2FF
60 140 0x465
125 257 0x6FE
150 302 0x7FF
Absolute Limits
Parameter Min Max Units
Operating voltage (V+) -0.3 6.0 V
Voltage at Analog output
I/O –Pins
(V
INA
, V
OUTA
)
-0.3 V
DDA
+ 0.3 V
Storage temperature
range
-50 150 °C
Operating data
Parameter Min Typ Max Units
Operating voltage
1
2.97 5.0 5.5 V
Supply current (I
V+
) @
V+ = 3.3 V, RT
30 45 80 µA
Ambient temperature
range (T
amb
)
-50 -- 150 °C
Output capacitance (C
L
) -- -- 15 nF
External capacitance
between V+ and Gnd
3
(C
V+
)
80 100 470 nF
Output load resistance
between signal and
Gnd (or V+)
47 -- -- kW
1
Operation in voltage range of 2.7 ... 2.97 V is possible with reduced
accuracy.
3
The connection of the blocking capacitor must be done as near as
possible to the connection pins of the component.
Temperature accuracy TSIC 206
Parameter Min Typ Max Units
T1: +10 ... 90 °C -0.5 0.5 °C
T2: -20 ... 110 °C -0.2 +0.4 0.95 °C
T3: -50 ... 150 °C 0 +0.9 2.0 °C
Accuracylevelas2σvalueplus1digit
quantising error
Temperature accuracy TSIC 306
Parameter Min Typ Max Units
T1: +10 ... 90 °C -0.3 ±0.3 0.3 °C
T2: -20 ... 110 °C -0.2 +0.3 0.95 °C
T3: -50 ... 150 °C 0 +0.9 2.0 °C
Accuracylevelas2σvalueplus1digitquantisingerror
SO8-Housing
SO8 Housing (150 mil, Standard SMT Technology, SOIC-8) as per
IEC 191-2Q: Type 076E35 B
Pin Nr. Name Description
1 V+ Operating voltage (3 ... 5.5 V)
2 Signal Temperature output signal
4 Gnd Ground
3, 5 - 8 TP/NC Test Pin / NC (not connected)
TO92-Housing
Small THT Housing, TO92 type
Pin Nr. Name Description
1 V+ Operating voltage (3 ... 5.5 V)
2 Signal Temperature output signal
3 Gnd Ground
TSIC™ DIGITAL SEMICONDUCTOR
TEMPERATURE SENSORS
B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen
Fon +49 771 83160 | Fax +49 771 831650 | info@bb-sensors.com | bb-sensors.com
2 / 2