User manual

OPERATION MANUAL
Technical changes reserved
0141 0316-119 17.08.2015
HYTEMOD-I2C-HUMIDITY MODULE WITH
VOLTAGE OUTPUT AND I²C-BUS
Application guidelines
First of all, the operating voltage should be selected as low as
possible, in case humidity values above 80% RH are to be measured.
Because of the compact size, the electronics can get heated slightly,
which can result in a loss of measuring accuracy.
The calibration at works is done at 8 V. The specied technical data
are valid for this operating voltage. Other congurations and special
calibrations as per customer requirements are also possible.
For connection of probes in longer routes, the
I
2
C-Bus, which is used outside the device, should not be used
internally, to avoid effect of inter-connection disturbances on internal
device communication. The EMV-guidelines are to be followed; use of
shielded lines is recommended.
Due to short time interruption of operating voltage, a RESET of humi-
dity probe can be initiated. If the operating voltage is adjustable, then
the pull up resistors of I
2
C Bus must be connected to the triggering
voltage.
For simplifying your product development, a communication Board
and also an USB-I
2
C-adapter is available – please contact us !
Outline drawing
Plastic housing with connection cable (Standard)
Product variants
The following overview describes the possible options and product
variants. You can send us your enquiry for the desired conguration;
we shall be pleased to give you an offer!
Housing
Unpackaged module, dimensions 37 x 12mm
Unpackaged module, with sensor holder and gasket D=12mm,
pressure sealed for probe tubes
In stainless steel housing Ø 12 x 90
Stainless steel housing with protection lter and connection cable
Module without housing with sensor head
Connection cable
If required, we can also supply module with connection cable.
The connection cable can be made with loose strands at the end or
with any type of plug.
Protection lter
Plastic protective case
Wire mesh lter
Plastic hydrophobic sinter lter
Stainless steel sinter lter
Membrane lter
You can get our complete overview on request!
Other options
The ASIC integrated in the module supports a variety of other opera-
ting modes:
PWM-outputs, contact outputs
SPI-Interface
One Wire Interface
ratiometric voltage output
3,3V Supply voltage
LIN-Bus
For further information, please visit our website:
www.bb-sensors.com
NC
B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen
Fon +49 771 83160 | Fax +49 771 831650 | info@bb-sensors.com | bb-sensors.com