User manual

OPERATION MANUAL
Technical changes reserved
0141 0316-207 21.08.2015
Fill level probe with pendulum
electrodes for level controller
DescriptionDescription
Technical data
Fill level probe with Pendulum electrodes
Sensor element Protected Hanging electrode
Switching point Impedance 15 ... 80 kOhm
Signal evaluation With AC impedance measurement
Temperature range 2 … 80 °C
Terminal box dimensions Approx. 84 x 84 x 60 mm
Probe material Stainless steel cable V2A, 1.4305,
corrosion resistant, 10 m
Housing material ABS, white
Connection RJ12-plug, 6-pin
Cable gland M12 x 1.5 (polyamide)
Connection cable TPE/Cu/TPE, 5x 0,14 mm²
Guarantee 24 months
Scope of supply Measuring probe with
documentation
CE-conformance 2004/108/EG
EMV-noise emission EN 61000-6-3:2011
EMV-noise withstanding EN 61000-6-1:2007
Article
Art.-No.
Fill level probe with pendulum
electrodes for level controller
ELEKT-PEND
Characteristic features
Conductive operating principle, electrolytic ll level measurement
High reliability, safe evaluation set-up
High grade stainless steel pendulum electrodes
AC voltage signal evaluation, low AC sensing current
Robust plastic housing
Connection to Level controller WLSW-12V, WLSW-24V und WLS-
GEH230V
Areas of application
Fill level probe for cisterns
Industrial applications
Agriculture
Application range
The probe is used for sensing the ll level at 4 stages in water or other
conductive liquids. The probe has ve hanging electrodes, which hang
out at different lengths inside the medium up to the switching point
of that stage. The hanging electrodes are in the form of corrosion
protected stainless steel weight (plumb), which are hung up with a
stainless steel rope. When the ll level in the container rises up to the
electrode, it gets wet and the presence of medium is registered due to
its conductivity.
Because of its exible constructional arrangement, the electrode
length can be individually set at desired switching points. The set
contains 10 m of stainless steel rope, so that each probe can be made
with over 2 m length.
Because of the hanging construction, contamination is prevented and
a reliable switching behaviour is also guaranteed in contaminated
media. Typical application areas which emerge out are e.g. as ll level
probe for water tanks or rain water cisterns .
B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen
Fon +49 771 83160 | Fax +49 771 831650 | info@bb-sensors.com | bb-sensors.com
1 / 3