User manual
Copyright © 2005, ZMD AG, 2005-05-17
4/8
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior
written consent of the copyright owner. The Information furnished in this publication is preliminary and subject to changes without notice.
ZMD31050
Advanced Differential Sensor Signal Conditioner
Application Note PRELIMINARY
2. First Example
The following example describes first
steps being familiar with KIT2 and
ZMD31050-software and ZMD31050.
• Plug all 3 delivered PCBs in order
Communication Board (CB) –
Sensor Signal Conditioner Board
(SSC) - Sensor Replacement Board
(SR) together and connect these to
the USB port of your computer
• Verify wrapped jumper connection
at SSC: K5 (Vsupply), K10 (Bridge
Mode Voltage) and at SR: K4 (BR)
• Start ZMD31050 software and
activate USB Port access via I2C
interface (refer chapter 1.1) and
verify accessed board and
command mode
• Open File menu and load
“31050_kit_default.31050” configuration. These file contains needed programming data for
ZMD31050 circuit to adjust/configure the ZMD31050 for application completely. These file or set of
data is called following “config”.
“31050_kit2_default.31050” config is loaded in software now.
These config is made for KIT2 to learn basics in handling of
KIT and ZMD31050. A short description of the loaded config
is displayed as info text. These config gain the input signal -
generated by the sensor replacement (SR) and was
calibrated to deliver 0.5/4.5V for SR potentiometer top/down
end adjustment. To verify this you have to do:
• Connect a DMM to the analog out of the ZMD31050. Use
“SSC: K10 – pin OUT“ and “SSC: K10 – pin GND”
measure point for this. Now the DMM measures the
analog output signal (VOUT). Refer ZMD31050 SSC
Board description for details.
• Adjust SR – potentiometer (poti) in middle position.
• Press “Write+Cyc_RAM” button: Loaded config is written
(Write) to ZMD31050 and started (Cyc_RAM) now.
• Check measured VOUT at the DMM: VOUT should be
approx. 2.5V and should be alter at changing SR – poti
adjustment.
• Measure VOUT for top and bottom position of the poti.
Loading a saved configuration
Write to 31050 and starting a config
Open “Sensor calibration“ dialogue