Datasheet
DATA SHEET
Technical changes reserved
0141 0316-124 06/2014 
Ceramic absolut pressure sensors
DS-KE-D-AXX
Description
Technical Data
Ceramic pressure sensors
Measuring principle Pressure measuring cell 
in thick lm technology
Measuring range 1...50 bar, 6 Typen
Linearity / Hysteresis / 
Reproducibility
< ±0,4 % Full Scale (FS)
Zero point-Offset -0,2…0 mV / V
Accuracy < ± 0,4 % FS 
Application temperature range -40...105 °C
Temperature error Gain 0...85 °C ≤ ±0,03 % FS / K 
Resistance value 10 kΩ ± 20 % 
Bridge supply voltage ≤ 30 VDC 
Dimensions Ø18 ±0,1 x see table
Connection Flat cable, 
RM 1.27 x 40 mm length
Characteristic features
•  Application range of 1 to 50 bar
•  For measurement of absolute pressure
•  Temperature compensated
•  Rugged, media-resistant model
•  Monolithic ceramic technology
•  Easy to install
•  Water and oil resistant
•  With connection leads
Typical areas of application
•  Pneumatics
•  Hydraulics
•  Pressure transmitter
•  Electronic pressure switch
•  Brake systems
•  Industrial applications
•  Fork lift trucks 
Features
The  pressure  sensors  of  series  DS-KE-D-A  are  ceramic  measuring 
cells in thick lm technology for measurement absolute pressure in li-
quids and gases.
As opposed to the ceramic relative pressure sensors DS-KE-D-R the 
back of the DS-KE-D-A sensors is evacuated and sealed. The sensors 
measure against vacuum.
In addition to being easily cleaned it is another advantage of the ab-
solute pressure sensors that the output signal is independent of the 
ambient pressure.
Because the material is a ceramic (Al
2O3), the sensor has an outstan-
ding stability against aggressive and corrosive media.
The delivery spectrum covers the entire pressure range of 1...50 bar FS 
with 6 variants for different measuring ranges.
The sensor is made up in the form of a full wheatstone bridge. The 
output signal is a pressure dependent differential voltage, that can be 
directly processed further with an instrument amplier or an ASIC.
A printed circuit board, matching with the sensor, is available which 
gives out an processed and calibrated voltage output of 0...10 V or 
current output of 4...20 mA.
Typical areas of application are in the eld of pneumatics, hydraulics 
and in industrial applications. 
B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen 
Fon +49 771 83160 | Fax +49 771 831650 | info@bb-sensors.com | bb-sensors.com
1 / 2