User manual
OPERATION MANUAL
Technical changes reserved
0141 0316-180 14.08.2015
Industrial pressure transmitter with
voltage or current output
Available Models
Connection layout
Pin Voltage output Current output
1 +DC 12…30 V +DC 10…30 V
2 GND 0 V
PRESSURE 4…20 mA
3 U PRESSURE 0…10 V ...
4 SHIELD SHIELD
Voltage output 0...10 V Current output 4...20 mAA
Connection diagram
Dimensions
With ¼“ manometer connection
For further information, visit our website: www.bb-sensors.com
Measuring range Burst pressure Order no. current output Order no. voltage output
-1…0 bar 4 bar DRTR-AL-20MA-RV0 DRTR-AL-10V-RV0
-1…1 bar 4 bar
RTR-AL-20MA-RV1
DRTR-AL-10V-RV1
0…1,6 bar 4 bar DRTR-AL-20MA-R1B6 DRTR-AL-10V-R1B6
0…2,5 bar 6,25 bar DRTR-AL-20MA-R2B5 DRTR-AL-10V-R2B
0…4 bar 10 bar DRTR-AL-20MA-R4B DRTR-AL-10V-R4B
0…6 bar 15 bar DRTR-AL-20MA-R6B DRTR-AL-10V-R6B
0…10 bar 25 bar DRTR-AL-20MA-R10B DRTR-AL-10V-R10B
0…16 bar 40 bar DRTR-AL-20MA-R16B DRTR-AL-10V-R16B
0…25 bar 62,5 bar DRTR-AL-20MA-R25B DRTR-AL-10V-R25B
0…40 bar 100 bar DRTR-AL-20MA-R40B DRTR-AL-10V-R40B
0…60 bar 150 bar DRTR-AL-20MA-R60 DRTR-AL-10V-R60B
0…100 bar 175 bar DRTR-AL-20MA-R100B DRTR-AL-10V-R100B
Relativdruckmessung, 0 bar entspricht Umgebungsdruck!
Attention
Please avoid extreme mechanical and inappropriate exposure.
The device/product is not suitable for potential explosive areas and
medical-technical applications.
B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen
Fon +49 771 83160 | Fax +49 771 8316-50 | info@bb-sensors.com | bb-sensors.com