Instructions
OPERATION MANUAL
Technical changes reserved
0141 0316-166 20.04.2016
Humidity/temperature measurement system 
Hytelog Multisensor with USB-interface
Software „PCLOG“
Besides storing data on hard disk, the software offers a very 
important feature of graphical repre-sentation of all measured and 
recorded channels in the form of humidity and temperature Vs time 
chart (online scriber function). By means of Drag & Click, the window 
section can be enlarged and the time or temperature axis can be 
scaled as desired. Besides the graphic view, representation is also 
possible in the form of a table. The in-between space is used for cap-
turing measured data series into a spreadsheet program (for example 
EXCELTM) or for word processing. All tables and graphic representa-
tions can be printed out in colour. In addition, simple monitoring and 
control functions are also integrated in the software. Limits can be set 
for each channel. An acoustic signal (Wave le) is given out when the 
values are exceeded. 
A speciality of the program is the integrated hx-calculator. This calcu-
lates further fteen parameters like dew point, absolute humidity, en-
thalpy, the wet bulb temperature, the vapour pressure and saturated 
vapour pressure etc. from the measured values of relative humidity 
and temperature.
First time operation
Connect the humidity measuring system to the USB- Interface of the 
Computer. Please start the software „PCLOG“. The required settings 
are done. If no interface is found, please choose the interface by 
hand. The record window is opened, when the measuring system is 
identied. If a sensor is identied, you can see the values on the left 
side. Then you can choose the value you want to record in the record 
window. Right click on the record window and choose „formating and 
axes“. In the menu you can choose the values you want to record. 
With the button „Start recording“ the record will be started.
Attention
Please avoid extreme mechanical and inappropriate exposure.
The device/product is not suitable for potential explosive areas and 
medical-technical applications.
Pin assignment
1 VDD 2 GND
3 SDA 4 SCL
5 GND 6 NC
Ordering numbers
Article Articleno.
Humidity and temperature measuring system 
Hytelog Multisensor inkl. 1 m USB-connection 
cable, operation manual and software
0567 0001
Humidity and temperature measuring system 
Hytelog Multisensor-Set 1 
inkl. digital humidity/temperature probe with I²C-
interface art.no. 0636 0011, cable length 3 m
1 m USB-connection cable and service case with 
operation manual and software
0570 0001
Humidity and temperature measuring system 
Hytelog Multisensor-Set 2 
inkl. digital humidity/temperature module with 
I²C-interface art.no. 0626 0110-05,
1 m USB-connection cable and service case with 
operation manual and software
0570 0002
Humidity and temperature measuring system 
Hytelog Multisensor-Set 3 
inkl. digital humidity/temperature probe HYT131 
art.no. 0636 0016, 
1 m USB-connection cable and service case with 
operation manual and software
0570 0004
Accessories Articleno.
Digitale humidity/temperature 
module with I²C interface
0626 0110-05
Connection cable for humidity/temperature probe, 
Art.-Nr. 0626 0110-05, Length 2 m, TPE-sheath
0409 3004
Digital humidity/temperature probe with I²C-
interface, cable length 3 m
0636 0011
Digital humidity/temperature 
probe HYT131
0636 0016
Please note that if up to 3 digital humidity / temperature probes 
are connected at the same time, the I²C addresses must be 
different.
Digital humidity / temperature sensor with I²C interface 0636 0011 
I²C address: 0x28
Digital humidity / temperature sensor with I²C interface 0636 0011-09 
I²C address: 0x29
Digital humidity / temperature sensor with I²C interface 0636 0011-10 
I²C address: 0x2A
B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen 
Fon +49 771 83160 | Fax +49 771 831650 | info@bb-sensors.com | bb-sensors.com