Controls, Indicators and Connector Specifications 
Switches 
Reset button 
Hold in for 0 to 2 seconds for hardware reset 
Hold in for 2 to 10 seconds for Console Mode (Do a hardware reset 
or recycle power to exit Console Mode) 
Hold in for more than 10 seconds to reset to factory defaults 
Indicators 
Serial LED 
(one per port) 
Color = Green 
On = Port open 
Flash = Data traffic 
Ethernet Link LED 
(one per port) 
Color = Green 
On = When Connected 
Flashing = Data traffic 
Ethernet Speed LED 
(one per port) 
Color = Yellow 
On = 100BaseTX 
Off = 10BaseT 
Ready LED 
Color = Green 
On Solid = System Initializing 
Flash (once per second) = System OK 
Flash (twice per second) = System Re-boot 
Off = System NOT OK 
Connectors 
10BaseT/100BaseTX Ethernet 
Single RJ-45F (8 pin) 
SC fiber 
SC connector 
ST fiber 
ST connector 
Serial 
VESR4x4D: four DB-9M connectors 
VESR4x4T: four pluggable terminal blocks 
DC Power 
3-position pluggable terminal block, or locking barrel connector 
Serial Interface Specifications 
Serial Interfaces 
Mode Selection 
RS-232/422/485 software selectable 
RS-232 lines 
TXD, RXD, RTS, CTS, DTR, DSR, DCD, GND  
RS-422 lines 
TXDA(-), TXDB(+), RXDA(-), RXDB(+), GND 
RS-485 lines (2 wire) 
Data(-), Data(+), GND 
RS-485 lines (4 wire) 
TXDA(-), TXDB(+), RXDA(-), RXDB(+), GND 
Baud Rates 
75, 150, 300, 600, 1200, 2400, 4800, 7200, 9600, 14400, 19200, 
28800, 38400, 57600, 115200, 230400 
Data Bits 
5, 6, 7, 8 
Parity 
None, even, odd, mark, space 
Stop bits 
1, 1.5, 2 
Flow control 
None, RTS/CTS, XON/XOFF 
RS-422/485 biasing 
Auto 1K ohm pullups and pulldowns 
RS-422/485 termination 
Termination with thru hole resistor (user supplied) 
RS-485 data control 
Auto control via MCU 