User manual

Section 3 - Installation and Initial Setup  Vlinx VESR4x4 Serial Server 
Page 21 of 70  Manual Documentation Number: VESR4x4-0712m 
  www.bb-elec.com/ 
  www.bb-europe.com/ 
Note:  Refer to Appendix D for connector pinout information. 
Figure 14.  VESR4x4 Connections 
Connecting VESR4x4 Serial Servers to a Network 
Ethernet Connection (10BaseT/100BaseTX) 
When connecting a serial server equipped with a 10BaseT/100BaseTX 
network  connection  (RJ45  connector)  to  an  Ethernet  network,  a  standard 
unshielded twisted-pair cable can be used. When installing this equipment 
in  industrial  or  other  electrically  noisy  environments,  STP  (shielded 
twisted  pair)  cable  is  strongly  recommended.  The  serial  server  has  an 
automatic MDIX interface which will sense the pinout of the network interface 
and provide a cross-over connection if required. 
Fiber Optic Connection 
When connecting a serial server equipped with  a  fiber optic interface 
to an Ethernet network, the appropriate fiber optic cable must be connected 
between  the  serial  server  and  the  network  interface.  The  TX  output  of  the 
serial server port must be connected to the RX input of the network interface 
and vice-versa. Refer to the list of VESR4x4 Serial Server Models (on page 8) 
for the supported fiber types, distances, and connectors. 
Ethernet Pass-through Port 
VESR424  serial  servers  are  equipped  with  an  additional  RJ45  network  port, 
also known as a pass-through port. This port can be used to connect additional 
Ethernet  devices,  such  as  a  local  workstation  or  second  serial  server,  to  the 
network. 