User Manual ULINX USR602 & USR604 2 & 4 Port USB Isolated Serial Converters
USR60x Series Documentation Number:USR60x-2112m This product was designed and manufactured in Ottawa, Illinois USA using domestic and imported parts by: International Headquarters: 707 Dayton Road Ottawa, IL 61350 USA Phone: (815) 433-5100 Website: www.bb-elec.com European Headquarters: Westlink Commercial Park Oranmore, Co. Galway, Ireland Phone: (+353) 91-792444 Website: www.bb-europe.
Table of Contents User Manual ................................................................................................1 Ulinx USR602 & USR604 ..............................................................................1 Overview .....................................................................................................5 Safety .............................................................................................................. 6 Product Feature Summary ..........................
USR602 Dimensions .......................................................................................... 35 USR604 Dimensions .......................................................................................... 36 Panel Mount Dimensions .................................................................................... 37 Appendix ...................................................................................................39 Loopback Test ...................................................
Section 1 - Overview SECTION 1 Overview 1 In This Section Safety ...................................................................... Product Feature Summary.......................................... About this Manual ..................................................... The USR60x family of products are industrial grade isolated USB to serial converters. They enable any host USB port to provide multiple RS-232, RS-422 or RS-485 two or four-wire serial interfaces.
Section 1 - Overview Safety All safety related regulations, local codes and instructions that appear in the literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Section 2 - Product Information SECTION 2 Product Information 2 In This Section USR60x Models ......................................................... Package Contents...................................................... Typical Applications / Modes of Operation ................... . USR60x Models The USR60x is a family of USB to serial converters.
Section 2 - Product Information Typical Applications / Modes of Operation • Addition of serial ports to PCs • Conversion of USB serial connection to: • RS-232 • RS-422 • RS-485 two-wire • RS-485 four-wire Page 8 of 45 Document Number: USR60x-0812m www.bb-elec.com/ www.bb-europe.
Section 3 - Quick Start Guide SECTION 3 Quick Start Guide The following Quick Start Guide outlines the basic steps to get your USR60x Converter up and running: 1. Check for included items • 2 or 4 port industrial USB to serial converter • Two meter USB cable • Panel mount adapters • DIN rail mount adapter • Driver CD • This quick start guide 2. Install the driver software (see "Installing the Driver" on page 13) • The CD contains a driver installation program.
Section 3 - Quick Start Guide • USR604: Connect 10 to 48VDC to terminal block and/or barrel jack 5. Check LED Indicators (on page 23) • Power indicated by green Pwr LED • Tx and Rx LEDs will indicate when data present 6.
Section 3 - Quick Start Guide 9. Perform a loopback test to verify that the converter is working. • Refer to the Loopback Test (on page 39) section Page 11 of 45 Document Number: USR60x-0812m www.bb-elec.com/ www.bb-europe.
Section 4 - Software Installation SECTION 4 Software Installation 3 In This Section Installing the Driver ................................................... Un-Installing the Driver.............................................. . Do not connect the converter to your PC until the Driver is installed. The driver is contained on the CD included with the converter. It is installed using an executable program. This program must be run on your PC before connecting the converter to your USB port.
Section 4 - Software Installation 1. Click Next. The license agreement dialog box will appear. Figure 3: End User License Agreement 2. Click Next. The program will install the drivers on your computer and the installation complete screen will appear. Figure 4: Installation Complete Screen Page 14 of 45 Document Number: USR60x-0812m www.bb-elec.com/ www.bb-europe.
Section 4 - Software Installation 3. When the installation is complete you can plug in the USB to Serial Converter. When you do this, the COM ports will be assigned. It may take up to 30 seconds to make the COM port assignments the first time you plug in the converter. 4. The driver software is now installed. 5. To verify that the communication port has been configured: a. Open the Control Panel b. Click System to open the System Properties dialog box. c. Select the Hardware tab. d.
Section 4 - Software Installation Un-Installing the Driver To un-install the driver for the USR60x converter: 1. Open the Control Panel 2. Click System to open the System Properties dialog box. 3. Select the Hardware tab. 4. Click Device Manager to open the Device Manager dialog box. 5. Expand Ports (COM & LPT) USB Isolated Serial Port should be listed as one of the COM ports. 6. Right-click the COM port listing for the converter (USB Isolated Serial Port) The following dialog box appears. 7. Click OK.
Section 5 - Hardware Installation SECTION 5 Hardware Installation 4 In This Section Installing and Mounting the USR60x ........................... Connecting Power ..................................................... Connecting to a PC .................................................... Connecting to the Serial Ports .................................... Termination and Biasing ............................................ Setting COM Port Operating Modes ............................. LED Indicators ......
Section 5 - Hardware Installation Installing and Mounting the USR60x USR60x converters come supplied with DIN rail mounting clips and panel mount adapters. Figure 6: DIN Rail Mounting Clip The DIN rail mounting clip is attached to the back of the unit using three machine screws (included). This mount enables the unit to be clipped directly to a standard DIN rail. Figure 7: USR602 with Panel Mount Adapters Panel mount adapters are attached to the unit with three machine screws on each side.
Section 5 - Hardware Installation • External power via pluggable terminal strip - 10 to 48 VDC, 16 watts max • External power via locking power jack - 10 to 48 VDC, 16 watts max Figure 8: Power Supply Connections When the unit is USB powered the current available to the converter may be limited by the USB host. If the converter is connected to an external USB hub the maximum available current may be insufficient to operate the converter. In that case an external power supply should be connected.
Section 5 - Hardware Installation Connecting to the Serial Ports The USR602 provides two serial ports; the USR604 has four. DB-9M connectors are used for RS-232, RS-422 and RS-485 two-wire and four-wire connections. Figure 10: DB-9M Serial Port Connectors The following illustration shows the pin numbering of the DB-9M connector. Figure 11: DB-9F Pin Numbering The following table shows the wiring pin-outs for RS-232, RS-422 and RS-485 two-wire and four-wire connections.
Section 5 - Hardware Installation Termination and Biasing USR60x converters include internal biasing resistors on the RS-422/RS485 interfaces. The values for internal biasing resistors are: Biasing: 1k ohms (default IN PLACE when in RS-422/485 modes) The biasing resistors are connected to the receive lines, pulling the RDA(-) line to ground and the RDB(+) line to a positive voltage. The bias resistor is automatically IN when you select RS-422/485 mode.
Section 5 - Hardware Installation • Switches 5 and 6 configure Port 3 • Switches 7 and 8 configure Port 4. Figure 133: USR604 DIP Switch and Power Connectors Operating modes are RS-232, RS-485 two-wire half-duplex, RS-485 four-wire full-duplex, and RS-422.
Section 5 - Hardware Installation LED Indicators USR602 converters include five LED indicators; USR604 converters include nine LED indicators. In both models one indicates the presence of power; the others indicate transmit and receive data present on each port.
Section 6 - Advanced User Settings SECTION 6 Advanced User Settings 5 In This Section Setting Serial Port Properties ...................................... Advanced Settings in Device Manager ......................... Modbus Basics .......................................................... . Serial port parameters and other advanced settings are configured on the USB Isolated Serial Port Properties and Advanced Settings windows, which are accessible via the Device Manager.
Section 6 - Advanced User Settings Setting Serial Port Properties 1. In Device Manager, expand Ports and double-click USB Isolated Serial Port to open the USB Isolated Serial Port Properties dialog box. Figure 177: Port Properties 2.
Section 6 - Advanced User Settings Advanced Settings in Device Manager To configure advanced settings, on the USB Isolated Serial Port Properties dialog, click Advanced... The Advanced Settings dialog appears. Figure 188: Advanced Settings Configure the advanced settings as required (refer to the following sections for details) and click OK to store the settings. COM Port Number When installing the drivers the first available COM port number is assigned to the first COM port on the USR60x device.
Section 6 - Advanced User Settings Select lower settings to correct performance problems at low baud rates. Select higher settings for faster performance. BM Options The BM Options dropdown list provides a setting for the Latency Timer. The latency timer is a form of time-out mechanism that counts from the last time data was sent from the USR60x back to the PC. If the latency timer expires, the USR60x will send any data it has available to the PC. It then resets and begins counting again.
Section 6 - Advanced User Settings Event On Surprise Removal - The Event On Surprise Removal option is generally left unselected. Set RTS On Close - Selecting the Set RTS On Close option will set the RTS signal on closing the port. Disable Modem Ctrl At Startup - This option is used to control the modem control signals DTR and RTS at startup. Devices that monitor these signals can enter the wrong state after an unplug-replug cycle on USB. Page 29 of 45 Document Number: USR60x-0812m www.bb-elec.com/ www.
Section 6 - Advanced User Settings Modbus Basics Modbus is an industrial data communications protocol that emerged in the mid-1970s and continues to be widely used in current industrial systems. Originally designed to link terminals with Modicon PLCs, it is simple, easy to learn and implement, and free to use. It quickly became a defacto standard in the industry and has been widely implemented with successful results.
Section 7 - Specifications SECTION 7 Specifications 6 In This Section Product Specifications ................................................ Certifications ............................................................. Default Settings ........................................................ USR602 Dimensions .................................................. USR604 Dimensions .................................................. Panel Mount Dimensions ............................................ .
Section 7 - Specifications Product Specifications Category Specification Models USR602, USR604 User documentation User manual: on CD and B&B website Data sheet: on B&B website Quick Start Guide: Printed Software Included on CD Operating Systems Supported Server 2008 R2, Windows 7, Windows 7 x64, Windows Server 2008, Windows Server 2008 x64, Windows Vista, Windows Vista x64, Windows Server 2003, Windows Server 2003 x64, Windows XP, Windows XP x64, Windows 2000 Dimensions USR602: 5.440in x 1.4in x 3.5in (13.
Section 7 - Specifications Certifications Category Specification Emissions FCC Class B, CISPR Class B (EN55022) CE EN61000-6-2:2005 – Heavy Industrial EN61000-4-2:2008 – (ESD) ±8kV contact, ±15kV air EN61000-4-3:2006 – (RI) 10V/m, 80 to 1000 MHz; 3 V/m, 1.3 to 2.7 GHz EN61000-4-4:2004 – (EFT Burst) ±2kV DC ports; ±1kV signal ports EN61000-4-5:2005 – (Surge) ±1kV Signal Ports EN61000-4-6:2005 – (CI) 10 VRMS , 0.
Section 7 - Specifications Default Settings Basic Settings Category Value Serial Interface RS-232 (both DIP switches off) Bits per second 9600 Data bits 8 Parity None Stop Bits 1 Flow Control None COM Port first available over COM port 4 Advanced Settings Category Value USB Transfer Size - Receive 4096 bytes (max) USB Transfer Size - Transmit 4096 bytes (max) Latency Timer 16 Minimum Read Timeout 0 Minimum Write Timeout 0 Serial Enumerator On Serial Printer Off Cancel If Power Off Off Event On Surprise Re
Section 7 - Specifications USR602 Dimensions Figure 19: USR602 Dimensional Diagram Page 35 of 45 Document Number: USR60x-0812m www.bb-elec.com/ www.bb-europe.
Section 7 - Specifications USR604 Dimensions Figure 20: USR604 Dimensional Diagram Page 36 of 45 Document Number: USR60x-0812m www.bb-elec.com/ www.bb-europe.
Section 7 - Specifications Panel Mount Dimensions Figure 21: USR602 Panel Mount Dimensions Figure 22: USR604 Panel Mount Dimensions Page 37 of 45 Document Number: USR60x-0812m www.bb-elec.com/ www.bb-europe.
Section 8 - Appendix SECTION 8 Appendix 7 In This Section Loopback Test .......................................................... Serial Port Wiring ...................................................... Loopback Test To verify the operation of the USB to serial converter perform a loopback test using the following procedure: 1. Connect the converter to the PC with a USB cable and install the driver using the procedure provided in the Software Installation (on page 13) section of this manual. 2.
Section 8 - Appendix 3. Enter a connection name and click OK. Figure 24: Selecting the COM Port 4. On the Connection using: dropdown list, select the port on the converter to be tested. 5. Click OK. Figure 25: Setting the Port Settings 6. On the Properties / Port Settings dialog, ensure Flow control is set to None. 7. Click OK. Page 40 of 45 Document Number: USR60x-0812m www.bb-elec.com/ www.bb-europe.
Section 8 - Appendix 8. Set the serial port to RS-232 mode by switching both associated DIP switches to Off. 9. Plug a loopback plug into the DB9M connector associated with the serial port to be tested. 10. Type some characters on the PC's keyboard. The characters should appear on the HyperTerminal window. Figure 26: Successful Hyperterminal Port Test 11. Remove the loopback plug and type more characters. No additional characters should appear on the HyperTerminal window.
Section 8 - Appendix Serial Port Wiring RS-232 Connections Figure 27: USR602 RS-232 Connections Page 42 of 45 Document Number: USR60x-0812m www.bb-elec.com/ www.bb-europe.
Section 8 - Appendix RS-485 Two-Wire Connections Figure 28: USR602 RS-485 Two-Wire Connections Page 43 of 45 Document Number: USR60x-0812m www.bb-elec.com/ www.bb-europe.
Section 8 - Appendix RS-422 and RS-485 Four-Wire Connections Figure 29: USR602 RS-422/485 Four-Wire Connections Page 44 of 45 Document Number: USR60x-0812m www.bb-elec.com/ www.bb-europe.
P Index Package Contents • 5 A Panel Mount Dimensions • 33 About this Manual • 4 Product Feature Summary • 4 Advanced Settings in Device Manager • 8, 23 Product Information • 5 Advanced User Settings • 21 Appendix • 35 B BM Options • 24 C Product Specifications • 27 Q Quick Start Guide • 7 R RS-232 Connections • 38 Certifications • 29 RS-422 and RS-485 Connections • 8, 40 COM Port Number • 23 RS-485 Two-Wire Connections • 8, 39 Connecting Power • 7, 14 S Connecting to a PC • 15 Safety • 4