User`s guide
33
●
●
●
●
●
Chapter 4
Parameter
#hex
/Sub#
Default
Brief Description (Note: Expanded description are
listed below)
Mode D
0
0=continuous or 1=batch.
Prime Time E
0
seconds, 0 decimal places.
Pause Time F 0 seconds, 0 decimal places.
feed time 10
40
seconds, 0 decimal places.
Initial Refill on 11
0
0 = no, 1 = yes
Auto Refill On 12 0 0=off, 1=on
Refill Start Low
Weight
13 10
Weight DP. No limits
Refill End Weight 14
100
Weight DP. No limits
Refill Stop High
Weight
15
100000
Weight DP. No limits.
Refill Low Shut
Off Weight
16
0
Weight DP. No limits.
Op Adjust 17
0
0=off,1= learning, 2= fixed.
Op Adjust % 18
0
6 decimal places.
Wait Time 19 0 Seconds, 0 decimal places. Must be > or = 0
REC Level 1A
20
1 decimal place. Must be > or = 0.
REC Time 1B
60
Seconds, 0 decimal places. Must be > or = 0
REC Shutdown 1C 0.0 0=no, 1=yes
Shutoff Percent 1D
0.0
0 decimal places. 0-100
Total 1E
0.0
Total DP
Batch Total 1F 0 Total DP. Must be > or = 0
Low Alarm Shut
Down Rate
20 0
Rate DP. No limits
High Alarm Shut
Down Rate
21 100
Rate DP. No limits
Alarm Delay 22
100
Seconds, 0 decimal places. Must be > or = 0.
Rate Setpoint 23
0
Rate DP. Must be > or = 0, < MAX RATE.
REC_P_Limit 24 10 1 decimal place. Must be > 0 and < or = 100.0.
Rate Calibration Parameters – See Rate Calibration Parameters section below
7 Rate Cal
Rates
xx32
7 rate calibration rates.
All use Rate DP, and must be > = 0.
0 rate 0032
0
Minimum rate always 0
1st rate
1032
None
Rate observed at 1st percent value when running a
5 pt cal. For a 2 pt cal this would be calculated.
2nd rate
2032
None
Rate observed at 2nd percent value when running a
5 pt cal or a 2 pt cal.
3rd rate
3032
None
Rate observed at 3rd percent value when running a
5 pt cal. For a 2 pt cal this would be calculated.
4th rate
4032
None
Rate observed at 4
th
percent value when running a
5 pt cal or a 2 pt cal.
5th rate
5032
None
Rate observed at 5
th
percent value when running a
5 pt cal. For a 2 pt cal this would be calculated.