Service manual

The display will show the parameter number then the word describing the function.
Press the [Tare] key to enter a parameter.
Press the [Zero] key to exit the factory parameter section. Display will show “
JP on”.
Remove the jumper. The scale will return to weighing.
When a parameter is entered by pressing the [Tare] key, the display will guide you
through the parameter selected and the options available.
The parameters available are:
F1 CAL To enter the Calibration
F2 rES Resolution selection, not valid for approved units
F3 CAP Select Capacity
F4 int Initial Zero Range
F5 rE Z Re-Zero Range
F6 SCS Successive Tare Enable
F7 Cnt Display the A/D counts
F8 ZE M Set zero method
F9 Ld M Set low voltage detect mode
8.1 F1 -CALIBRATION
F1 CAL
Press [Tare]
UnLoAd
Empty the pan by removing the load, if there is any
and press [Tare]
Ld1 XX kg
Load the first calibration weight and press [Tare]
Ld2 XX kg
Load the second calibration weight and press [Tare]
PASS
Calibration is complete. Remove the calibration weight.
Or, “FAiL L
This means calibration has failed. Remove the
calibration weight and repeat the process.
JP on
Remove the jumper or shorting of the pins whichever
is used. The scale will return to normal weighing.
© Adam Equipment Company 2007
12