Service manual
8.0 FACTORY PARAMETERS
The factory parameters are used performing the factory calibration, setting the capacity
and other basic settings.
To access these parameters place a jumper into the pins on the main PCB (marked as
position J4) through a hole provided on the base of the scale.
Turn the scale upside down.
Remove the seal covering the hole to access the PCB.
Place a jumper through the hole into the pins. If a
jumper is not available, short the pins.
Turn on the scale using the switch on the base.
“
P _ _ _ _”
Enter
“2006” and press [Tare]
After the jumper has been placed in the position shown, apply power to the scale.
The display will show the software revision number and then ask for a code number,
“P _ _ _ _ “.
Enter the number 2006 and press [Tare].
The display will show the first parameter “F1 CAL”. To scroll through other parameters
press the [Func] key.
© Adam Equipment Company 2007
11