Serial Server DB-9 Pin-out in RS-485 Mode 
RS-485 
Signal Name 
Direction RS-485 DB9M 
Pin 
Data B (+)  In/Out  DATA B (+)  3 
Data A (−)  In/Out  DATA A (−) 4 
Signal Ground  ---  GND  5 
Figure 70.  DB-9 Pin-out in RS-485 Mode 
N
N
o
o
t
t
e
e
:
:
Some RS-485 devices are marked opposite the RS-485 standard, 
which defines the Data B line as positive relative to Data A during a 
Mark state before enabling the transmitter, and after transmitting 
before tri-stating. If an RS-485 device does not respond, try swapping 
the Data B and Data A lines. 
Figure 71.  2-wire RS-485 Connection 
To connect 4-Wire RS-485 devices, the RS-422 Mode can be used 
provided the 
Serial Server will be connected as a master in a single 
master system. If using multiple masters, the Serial Server cannot be 
used, as it does not tri-state the transmitter in RS-422 mode. 
RS-485 Connections 
80  Appendix D  Manual Documentation Number: ESP901-902_4105m 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com