User manual
 Using Telnet 
Manual Documentation Number: ESP901-902_4105m   Chapter 11  63 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com 
C
C
H
H
A
A
P
P
T
T
E
E
R
R
1
1
1
1
:
:
U
U
s
s
i
i
n
n
g
g
T
T
e
e
l
l
n
n
e
e
t
t
Telnet can be used to configure the Serial Server from any PC on the 
LAN. The 
Telnet window displays the same configuration information 
shown in Console Mode and allows server properties to be configured. 
N
N
o
o
t
t
e
e
:
:
See Chapter 5 for details on Server Properties. 
Configuration Using Telnet 
Step 1:   Ensure the PC and Serial Server are connected to the LAN. 
Step 2:  Apply power to the 
Serial Server. The power and ready LED 
will light. 
Step 3:  If the DIP switches on the 
Serial Server all are in the ON 
position (Console mode), switch them to the OFF position. 
The Serial Server will revert to the operational mode it was in 
before the switches were all set to ON. 
Step 4: From the 
Desktop, click Start, then Run. The Run dialogue 
box will open. 
Step 5:  Type in 
Telnet and the IP address of the Serial Server to be 
configured, then click OK. 
Figure 55.  The Run dialogue box 
N
N
o
o
t
t
e
e
:
:
The Serial Server must be in RS-232, RS-422 or RS-485 mode before you can 
Telnet to it and access the configuration screens. If it was last configured in 
Console mode you may not be able to access it using Telnet. In this case use 
ESP Manager, Console Mode or Web Server for configuration. 
Using Telnet 
64  Chapter 11  Manual Documentation Number: ESP904-0504 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com 
Step 6.  The Telnet window will open (unless the server is still in 
Console mode) and the Server screen will appear. 
Navigating the Configuration Menu 
There are six Telnet  screens:  Server,  Network,  Serial Mode, 
Operation, Monitor and Configuration.  Tab,  Back Space and arrow 
keys can be used to highlight the desired function on the screen list. 
Pressing 
Enter moves the cursor to the first field with the current 
screen. The configuration fields can be changed by pressing Enter and 
selecting from the list that appears. The 
Escape key moves the cursor 
back to the screen list. Pressing the Space Bar refreshes the page. 