Instruction Manual

SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
PEAKCURRENT
PEAKPOWER Note.6
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
DCOKREALY CONTACTRATINGS(max.)
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
1500ms,60ms/230VAC30 atfullload00ms,60ms/115VAC
20ms/230VAC20ms/115VACatfullload
88~264VAC124~370VDC
47~63Hz
89%
0.93/230VAC0.96/115VACatfullload
1.4A/115VAC0.7A/230VAC
29~33V
91%
56~65V
90.5%
35A/115VAC70A/230VAC
<1mA /240VAC
Normallyw morethan3 andthenshutdowno/pvoltageorkswithin110~150%ratedoutputpowerfor seconds
14~17V
>150%ratedpower,constantcurrentlimitingwithauto-recoverywithin3secondsandshutdowno/pvoltageafter3seconds
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
95 5 (TSW:detectonheatsinkofpowerswitch)
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
UL508 TUVEN60950-1approved,
CompliancetoEN55022(CISPR22)ClassB
CompliancetoEN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2),EN61204-3,heavyindustrylevel,
criteria A,SEMIF47approved
-25~+70 (Refertooutputloadderatingcurve)
60Vdc/0.3A,30Vdc/1A,30Vac/0.5A resistiveload
20~95%RHnon-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50
Component:10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes;Mounting:CompliancetoIEC60068-2-6
289.9Khrsmin.MIL-HDBK-217F(25 )
40*125.2*113.5mm(W*H*D)
0.67Kg;20pcs/14.4Kg/1.16CUFT
POWERFACTOR (Typ.)
SDR-120-24 SDR-120-48
24V 48V
5A 2.5A
0~5A 0~2.5A
120W 120W
7.5A 3.75A
100mVp-p 120mVp-p
24~28V 48~55V
1.0% 1.0%
0.5% 0.5%
1.0% 1.0%
SDR-120-12
12V
10A
0~10A
120W
15A
180W(3sec.)
100mVp-p
12~14V
1.0%
0.5%
1.0%
Features :
SDR-120 series
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC O/P-DCOK:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:>100MOhms/500VDC/25 /70%RH
EMICONDUCTION&RADIATION
ENVIRONMENT
SAFETY &
FUNCTION
EMC
(Note4)
PROTECTION
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.
In case the adjacent device is a heat source, 15mm clearance is recommended.
6. 3 seconds max., please refer to peak loading curves.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
120WSingleOutputIndustrialDINRAIL withPFCFunction
High efficiency 91% and low power dissipation
Built-in active PFC function, PF>0.93
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
UL 508 (industrial control equipment) approved
EN61000-6-2(EN50082-2) industrial immunity level
100% full load burn-in test
3 years warranty
150% peak load capability
Built-in DC OK relay contact