Specifications

S7-200 Programmable Controller System Manual
464
RS-232/PPI Multi-Master Cable and USB/PPI Multi-Master Cable
Table A-66 RS-232/PPI Multi-Master Cable and USB/PPI Multi-Master Cable Specifications
Description
Order Number
S7-200 RS-232/PPI Multi-Master Cable
6ES7 901 --3CB30--0XA0
S7-200 USB/PPI Multi-Master Cable
6ES7--901-- 3DB30--0XA0
General Characteristics
Supply voltage 14.4 to 28.8 VDC 14.4 to 28.8 VDC
Supply current at 24 V nominal supply 60 mA RMS max. 50 mA RMS max.
Direction c hange delay: RS-232 stop bit edge
received to RS-485 transmission disabled
-- --
Isolation RS-485 to RS-232: 500 VDC RS-485 to USB: 500 VDC
RS-485 Side Electrical Characteristics
Common mode voltage range --7 V to +12 V, 1 second, 3 V RMS continuous --7 V to +12 V, 1 second, 3 V RMS continuous
Receiver i nput impedance 5.4 K min. including termination 5.4 K min. including termination
Termination/bias 10K to+5VonB,PROFIBUSpin3
10K to GND on A, PROFIBUS pin 8
10K to+5VonB,PROFIBUSpin3
10K to GND on A, PROFIBUS pin 8
Receiver threshol d/sensitivity +/--0.2 V, 60 mV typic al hysteresis +/ --0.2 V, 60 mV typic al hysteresi s
Transmitter differential output voltage 2 V min. at R
L
=100 ,
1.5 V min. at R
L
=54
2Vmin.atR
L
=100 ,
1.5 V min. at R
L
=54
RS-232 Side Electrical Characteristics
Receiver i nput impedance 3K min. --
Receiver threshol d/sensitivity 0.8 V min. low, 2.4 V max. high
0.5 V ty pical hysteresis
--
Transmitter output voltage +/-- 5 V min. at R
L
=3K --
USB Side Electrical Characteristics
Full speed (12 MB/s ), Human Interface Device (HID)
Supply current at 5V -- 50 mA max.
Power down current -- 400 uA max.
Features
The S7-200 RS-232/PPI Multi-Master Cable comes factory set for optimal performance with the
STEP 7--Micro/WIN 3.2 Service Pack 4 (or later) programming package. The factory setting for
this cable is different than for the PC/PPI cables. Refer to Figure 1 to c onfigure the cable for your
application.
You can configure the S7-200 RS-232/PPI Multi-Master Cable to operate the same as the PC/PPI
cable and to be compatible with any version of a STEP 7--Micro/WIN programming package by
setting Switch 5 to the PPI/Freeport setting and then selecting y our required baud rate.
The USB cable requires STEP 7 --Micro/WIN 3.2 Service Pack 4 (or later) programming package
for operation.
Tip
For more information about using these c ables, refer to Chapter 7, Communicating over a
Network.