Specifications

S7-200 Programmable Controller System Manual
444
;================================================
; GSD File for the EM 277 PROFIBUS-DP with a DPC31
; MLFB : 6ES7 277- 0AA2.-0XA0
; DATE : 26-March-2001
;================================================
#Profibus_DP
;General parameters
GSD_Revision = 1
Vendor_Name = ”Siemens”
Model_Name = ”EM 277 PROFIBUS-DP”
Revision = ”V1.02”
Ident_Number = 0x089D
Protocol_Ident = 0
Station_Type = 0
FMS_supp = 0
Hardware_Release = ”1.00”
Software_Release = ”1.02”
9.6_supp = 1
19.2_supp = 1
45.45_supp = 1
93.75_supp = 1
187.5_supp = 1
500_supp = 1
1.5M_supp = 1
3M_supp = 1
6M_supp = 1
12M_supp = 1
MaxTsdr_9.6 = 60
MaxTsdr_19.2 = 60
MaxTsdr_45.45 = 250
MaxTsdr_93.75 = 60
MaxTsdr_187.5 = 60
MaxTsdr_500 = 100
MaxTsdr_1.5M = 150
MaxTsdr_3M = 250
MaxTsdr_6M = 450
MaxTsdr_12M = 800
Redundancy = 0
Repeater_Ctrl_Sig = 2
24V_Pins = 2
; Slave-Specification:
OrderNumber=”6ES7 277-0AA2.-0XA0”
Periphery=”SIMATIC S5”
Slave_Family=10@TdF@SIMATIC
Freeze_Mode_supp = 1
Sync_Mode_supp = 1
Set_Slave_Add_Supp = 0
Auto_Baud_supp = 1
Min_Slave_Intervall = 1
Fail_Safe = 0
Max_Diag_Data_Len = 6
Modul_Offset = 0
Modular_Station = 1
Max_Module = 1
Max_Input_len = 128
Max_Output_len = 128
Max_Data_len = 256
; UserPrmData-Definition
ExtUserPrmData=1 ”I/O Offset in the V-memory”
Unsigned16 0 0-10239
EndExtUserPrmData
; UserPrmData: Length and Preset:
User_Prm_Data_Len=3
User_Prm_Data= 0,0,0
Max_User_Prm_Data_Len=3
Ext_User_Prm_Data_Const(0)=0x00,0x00,0x00
Ext_User_Prm_Data_Ref(1)=1
;================================================
; Continuation of GSD File
;================================================
; Module Definition List
Module = ”2 Bytes Out/ 2 Bytes In - ” 0x31
EndModule
Module = ”8 Bytes Out/ 8 Bytes In - ” 0x37
EndModule
Module = ”32 Bytes Out/ 32 Bytes In -”
0xC0,0x1F,0x1F
EndModule
Module = ”64 Bytes Out/ 64 Bytes In -”
0xC0,0x3F,0x3F
EndModule
Module = ”1 Word Out/ 1 Word In - 0x70
EndModule
Module = ”2 Word Out/ 2 Word In - 0x71
EndModule
Module = ”4 Word Out/ 4 Word In - 0x73
EndModule
Module = ”8 Word Out/ 8 Word In - 0x77
EndModule
Module = ”16 Word Out/ 16 Word In - ” 0x7F
EndModule
Module = ”32 Word Out/ 32 Word In -”
0xC0,0x5F,0x5F
EndModule
Module = ”2 Word Out/ 8 Word In -”
0xC0,0x41,0x47
EndModule
Module = ”4 Word Out/ 16 Word In -
0xC0,0x43,0x4F
EndModule
Module = ”8 Word Out/ 32 Word In -
0xC0,0x47,0x5F
EndModule
Module = ”8 Word Out/ 2 Word In -”
0xC0,0x47,0x41
EndModule
Module = ”16 Word Out/ 4 Word In -
0xC0,0x4F,0x43
EndModule
Module = ”32 Word Out/ 8 Word In -
0xC0,0x5F,0x47
EndModule
Module = ”4 Byte buffer I/O -” 0xB3
EndModule
Module = ”8 Byte buffer I/O -” 0xB7
EndModule
Module = ”12 Byte buffer I/O -” 0xBB
EndModule
Module = ”16 Byte buffer I/O -” 0xBF
EndModule
Figure A-31 Listing of the GSD File for the EM 277 PROFIBUS Module