Product data

42
MSLoad
!
IMPORTANT: Some controllers (like the TSMPPT) contain
two microprocessors. These units will need a rmware
update for each processor. Such update les will be
designated ‘A’ and ‘B’.
The preceding steps assume the Morningstar unit has an on-board RS-232 connection. The next
sectiondescribeshowtoupdatethermwareofaunitwithoutanon-boardDB-9(RS-232)port.
6.3 Firmware Upgrades Without A DB-9 (RS-232) Connection
Someproductsdonothaveanon-boardserialport,butcanstillhavetheirrmwareupgraded.
For controllers/inverters (not Meter accessories) with a standard RJ-11 MeterBus
TM
port, an MSC
adapter (Section 2.1.1) is needed. The adapter will interface the controller/inverters RJ-11 port
with your computer’s (or USB adapter’s) serial port.
SomeproductshaveanRJ-11portbutcannotbermwareupdateddirectly.Anexampleisthe
TriStar Meter 2 (TS-M-2). Updates to the TS-M-2 are done through use of a TriStar or TriStar
MPPT.
TheRS-232portusedtoupdateTSorTSMPPTrmwareisthesameusedtoupdatetheTS-M-2
rmware.TheMeterisconnectedtotheTS/TSMPPTviaanRJ-11MeterBus
TM
cable and the TS
unit is used as a bridge to upload the new software to the Meter accessory.
Forbothsituations,thermwareupgradeprocedureisthesameasoutlinedinthepreviousSec-
tion 6.2.
PleaserefertotheTechSupportpageontheMorningstarwebsiteifyouhavedifcultyupgrading
yourcontroller’srmware.