2.23 @AAEAT
Description : Enable Alarm
Syntax : @AAEAT[CHK](cr)
@ delimiter character
AA address of setting module (00 to FF)
EA command for enable alarm.
T alarm type, M=momentary alarm, L=latch alarm.
Response : Valid Command : !AA[CHK](cr)
Invalid Command : ?AA[CHK](cr)
Syntax error or communication error may get no re-
sponse.
! delimiter for valid command
? delimiter for invalid command
AA address of response module(00 to FF)
Example :
Command : @01EAM Receive : ?01
Set address 01 momentary alarm, return success.
Related Command :
Sec.2.26 @AADA, Sec.2.27 @AACA
Related Topic :
Sec.3.6 High/Low Alarm
Note : The command is for I-7011/11D/11P/11PD only