ILinx FOSTCDRI-PH-xx Fiber Optic Converter
This Quick Start Guide
Additional Items Required but not included
o A 10 to 48 VDC Power Supply. The Converter
draws 2.6W Max.
2
2
.
.
I
I
n
n
f
f
o
o
r
r
m
m
a
a
t
t
i
i
o
o
n
n
U
U
L
L
C
C
l
l
a
a
s
s
s
s
1
1
D
D
i
i
v
v
2
2
1. Refer to the Nonincendive Field Wiring Apparatus
Control Drawing for important information .
2. Power, Input / output (I/O) wiring for the end use
enclosure must be in accordance with Class 1
Division 2 wiring methods (Article 501.10(B) of the
National Electric Code, NFPA 70) and in
accordance with the local authority having
jurisdiction.
3. Maximum ambient air temperature 85°C.
4. Temperature rating of field installed conductors
105°C. Use Copper Wire Only.
5. These devices must be installed in end use
enclosure suitable for the location.
6. WARNING EXPLOSION HAZARD
SUBSTITUTION OF COMPONENTS MAY IMPAIR
SUITABILITY FOR CLASS 1, DIVISION 2.
7. WARNING EXPLOSION HAZARD: DO NOT
DISCONNECT EQUIPMENT UNLESS POWER
HAS BEEN SWITCHED OFF OR THE AREA IS
KNOWN TO BE NON-HAZARDOUS.
8. WARNING THIS APPARATUS IS SUITABLE
FOR USE IN CLASS 1 DIVISION 2, GROUPS A,
B, C, AND D OR NONHAZARDOUS LOCATIONS
ONLY.
Quick Start Guide
ILinx FOSTCDRI-PH-xx
Triple Isolated Serial to Fiber
Optic Converter
3
3
.
.
F
F
r
r
o
o
n
n
t
t
/
/
B
B
a
a
c
c
k
k
P
P
a
a
n
n
e
e
l
l
,
,
T
T
B
B
1
1
A
Power LED
Red, ON When Power Applied
B
Data LEDs
Green. LEDs Flash When Data is on
Port. Left LED’s for Fiber, Right
LED’s for Copper
C
Fiber Optic
Connectors
ST or SC, MM or SM, depending on
model.
D
Serial TB
5 Position, Removable
E
Ground Lug
Chassis Ground to Earth Ground
F
DIP Switch
Used to Configure
G
Serial Mode
Switch
Used to configure serial mode. RS-
232 or RS-422/485.
H
Power TB
2 Position, Removable
TB1 RS-422/485
RS-485 2-Wire
RS-422/485 4-Wire
---
TDA(-)
---
TDB(+)
DATA A(-)
RDA(-)
DATA B(+)
RDB(+)
Ground
Ground
TB1 RS-232
Signal
Direction
RD
Output
---
---
TD
Input
---
---
Ground
----
4
4
.
.
C
C
o
o
n
n
f
f
i
i
g
g
u
u
r
r
a
a
t
t
i
i
o
o
n
n
D
D
I
I
P
P
S
S
w
w
i
i
t
t
c
c
h
h
Highlighted settings indicate factory default.
Communications Mode
Switch
1
2
3
4
RS-485
2-Wire
Half Duplex
ON
ON
ON
ON
RS-485
4-Wire
Full Duplex
ON
OFF
OFF
OFF
RS-422
Full Duplex
OFF
OFF
OFF
OFF
Built-in Termination Resistor
Switch
5
Use the 120Ω Built-in Termination
ON
Use External or No Termination
OFF
Built-in Transmit Bias Resistor
Switch
6
Use External or No Bias Resistor
ON
Use the 1.2K Ω Transmit Bias Resistor
OFF
Built-in Receive Bias Resistor
Switch
7
Use External or No Bias Resistor
ON
Use the 1.2K Ω Receive Bias Resistor
OFF
Fiber Optic Mode
Switch
8
Multi-drop Ring
ON
Point-to-Point
OFF
For an explanation of RS-485 termination and biasing
requirements, refer to B&B Electronics’ RS-485
application note. This publication can be downloaded
at: www.bb-elec.com