For descriptive purposes this Quick Start Guide considers a typical
configuration consisting of a
PC connected via an Ethernet LAN to an
ESR902 Serial Server connected to the RS-232 port of a serial device.
Hardware Setup
LAN
Etherne t
cable
Ethernet
cable
RS-232
cable
Ser ial Device
ESR902
PC
Figure 2. Typical Hardware Setup
Step 1: Connect the Serial Server to the network using a standard network
cable.
Step 2: Connect the
Serial Server to the RS-232 port on the serial device.
N
N
o
o
t
t
e
e
:
:
If the serial device is configured as a DCE use a straight-through serial cable. If
the serial device is configured as a DTE use a crossover (null modem) cable.
Step 3: Set the Run/Console DIP switch to the Run position.
Step 4: Apply power to the
Serial Server.
Software Installation
Using the CD included with the Serial Server, install the VLINX Manager
software on the configuring computer.
Manual Documentation Number ESR90x-1705m Chapter 1 5
B&B Electronics Mfg Co Inc – 707 Dayton Rd - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Introduction
Serial Server Configuration
Step 1: Open the ESP Manager software. It will automatically search for
any reachable (ESP or ESR) Serial Servers. A list of all Serial
Servers connected to the LAN will appear in the Serial Server List
window.
Step 2: Double click the desired Serial Server port on the list to bring up the
Server Properties configuration screen.
Figure 3. The Server Properties Window
Step 3: Change the Server Properties as required.
Enable
DHCP to allow the Serial Server to generate its own IP
address
OR
Obtain appropriate static
IP, Netmask and Gateway addresses
from your Network Administrator (recommended)
Set the
Serial Port Mode property to RS-232 to match the serial
device connected to the
Serial Server.
Set
Baud Rate, Data/Parity/Stop, and Flow Control to match
the configuration of the serial device connected to the
Serial
Server
port
Step 4: When the parameters have been set, click
Update. Following the
prompts in the dialogue boxes,
Restart the Serial Server and
Search all reachable servers again.