Technical data

ESR90x Technical Data
Default Server
Settings
Server Name ESR901 or ESR902 or ESR904
Serial Number: xxxxxxxxx (printed on bottom of unit)
Password: Blank
DHCP: Disable
IP Address: 192.168.0.1
Net Mask: 255.255.255.0
Gateway: 192.168.0.254
MAC Address: Fixed – see bottom label
Version&Date: current firmware version number & date
Serial server port: 1
Baud Rate: 9600
Data//Stop: 8-1
Parity: None
Flow Control: None
TCP/UDP Protocol: ESR901 serial port: TCP
ESR902 Ports 1 & 2: TCP
ESR902 Ports 1, 2, 3 & 4: TCP
Serial timeout: 0 seconds
TCP alive timeout: 0 minutes
Connection Mode: Server
Delimiter HEX 1: 00
Delimiter HEX 2: 00
Force transmit: 0 ms
TCP/UDP port: ESR901/902/904 Port 1: 4000
ESR902/904 Port 2: 4001
ESR904 Port 3: 4002
ESR904 Port 4: 4003
Serial port mode: ESR901/902/904 (all ports): RS-232
Max connection: 1
Remote IP Address: 255.255.255.255
DIP switch settings: ESR901: 1 = Run
2 = DB9
ESR902: Run
ESR904: Run
Manual Documentation Number: ESR90x-1705m Chapter 12 67
B&B Electronics Mfg Co Inc – 707 Dayton Rd - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
ESR90x Technical Data
4.46 cm
15.52 cm
9.70 c m
0.76 c m
1.09 cm
3. 23 c m
7.62 cm
2.60 cm
0.96 cm
0.48 cm
4.44 cm
2.66 cm
3.01 cm
0.81 cm
0.61 cm
0.97 cm
0.81 cm
10.46 cm
12.65 cm
1.44 cm
1. 44 cm
6.96 cm
1.72 cm 6.84 cm
1
GN D
AC I n
AC/DC+ In
Ba c kup D C + In
Link
Ready
Po wer
Reset
Run
Co ns ol e
Et he rn et
1
RX TX
V ol tage R an ge:
9-48VDC
8-24VAC
ESR901
1
RS-232/422/485
G
N
D
C
T
S
/
T
X
-
T
X
/
T
X
+
R
X
/
R
X
+
R
T
S
/
R
X
-
D B9 Ter mi na l
Figure 46. Dimensional Diagram of the ESR901
4.46 cm
15.52 cm
9. 70 c m
0.76 c m
1.09 cm
3.23 cm
7.62 cm
2.60 cm
0.96 cm
0. 48 c m
4.44 cm
2.66 cm
3.01 cm
0.81 cm
0.61 cm
0.97 cm
0.81 cm
10.4 6 cm
12.65 cm
1.44 cm
1. 44 cm
6.96 cm
1.72 cm 6.84 cm
1
GND
AC In
AC/DC+ In
Bac kup D C+ In
Link
Ready
Power
Reset
Run Console
Et hern et
2
1
RX TX RX TX
V olt age R ang e:
9-48VDC
9-48VAC
ESR902
Figure 47. Dimensional Diagram of the ESR902
68 Chapter 12 Manual Documentation Number: ESR90x-1705m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com