User Manual Elinx EIRM-EXTEND Managed Hardened 10/100BASE-TX Ethernet Extender Model EIRM-EXTEND Documentation Number: EIRM-EXTEND-0411m Manual Documentation Number: EIRM-EXTEND-1412m Table of Contents i B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.
707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax (815) 433-5105 Website: www.bb-elec.com Sales e-mail: orders@bb-elec.com -- Fax (815) 433-5109 Technical Support e-mail: support@bb.elec.com -- Fax (815) 433-5104 European Headquarters B&B Electronics Westlink Commercial Park -- Oranmore, Co. Galway, Ireland Phone +353 91-792444 -- Fax +353 91-792445 Website: www.bb-europe.com Sales e-mail: sales@bb-europe.com Technical Support e-mail: support@bb-europe.
This document contains information that is proprietary and confidential to B&B Electronics Mfg. Co. Inc. The methods described herein are for the exclusive use of B&B Electronics authorized personnel. Any unauthorized use or dissemination of the information contained in the document is strictly forbidden. Manual Documentation Number: EIRM-EXTEND-1412m Table of Contents iii B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.
Table of Contents Chapter 1 – Introduction 1 PRODUCT OVERVIEW ................................................................................ 1 PRODUCT FEATURES ................................................................................. 1 PACKING LIST ........................................................................................... 2 One-Channel Hardened Managed Ethernet Extender 3 PORTS ....................................................................................................
Retrain VDSL ..................................................................................... 22 System Log.......................................................................................... 23 VDSL Status........................................................................................ 24 RESTART ................................................................................................. 24 Restart System ...............................................................................
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.
Chapter 1 – Introduction The Hardened Managed Ethernet Extender provides one channel Ethernet over existing voice grade copper wire. This Hardened Managed Ethernet Extender solution is perfectly fitted in the industrial applications or rugged environment. Product Overview Product Features • • • • • • • • • • Meets NEMA TS1/TS2 Environmental requirements: temperature, shock, and vibration for traffic control equipment.
• Field Wiring Terminal: Use Copper Conductors Only, 12-24 AWG torque value 7 lb-in. • Operating temperature range @ -40℃ to 75℃ (-40℉ to 167℉). Tested for functional operation @ -40℃ to 85℃ (-40℉ to 185℉). UL508 Industrial Control Equipment certified Maximum Surrounding Air • • Temperature @ 75℃ (167℉). For use in Pollution Degree 2 Environment. Supports Din-Rail or Panel Mounting installation.
One-Channel Hardened Managed Ethernet Extender Ports The Hardened Managed Ethernet Extender provides one Ethernet port RJ-45 (10/100Mbps) port and one Ethernet Extender port. The Ethernet Extender port, uses RJ-11 and Terminal Block connectors that will auto senses the speeds 1/3/5/10/15/20/25/30/40/50Mbps. Ethernet Extender Mode Settings Ethernet Extender mode settings are DIP switch (Dual Inline Package) selectable. The switch is located on the top panel of the Hardened Managed Ethernet Extender.
Front Panel & LEDs LED Indicators The LED indicators give you instant feedback on status of the Hardened Managed Ethernet Extender: LEDs State Indication Power 1 Power 2 Power 3 Ethernet Link/ACT FDX Steady Power on Off Power off Steady A valid Ethernet connection established Flashing Transmitting or receiving Ethernet data ACT stands for ACTIVITY Off Neither valid Ethernet connection transmitting/receiving Ethernet data Steady Ethernet Connection in full-duplex mode FDX stands for FULL-DUPLEX
The 10/100Base-TX and Ethernet Extender Connectors The 10/100Base-TX Connection The following lists the pinouts of 10/100Base-TX RJ-45 port. Pin Regular Ports Uplink ports 1 Output Transmit Data + Input Receive Data + 2 Output Transmit Data - Input Receive Data 3 Input Receive Data + Output Transmit Data + 4 NC NC 5 NC NC 6 Input Receive Data Output Transmit Data 7 NC NC 8 NC NC The Ethernet Extender Connection The RJ-11 and Terminal Block port pinouts: Pin 3: Tip, Pin 4: Ring.
Installation This chapter gives step-by-step installation instructions for the Hardened Managed Ethernet Extender. Selecting a Site for the Equipment As with any electric device, you should place the equipment where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements: • • • • • The Surrounding Air temperature should be between -34 to 60 degrees Celsius.
DIN Rail Mounting • Fix the DIN rail attachment plate to the back panel of the Hardened Managed Ethernet Extender. • Installation: Place the Hardened Managed Ethernet Extender on the DIN rail from above using the slot. Push the front of the Hardened Managed Ethernet Extender toward the mounting surface until it audibly snaps into place. • Removal: Pull out the lower edge and then remove the Hardened Managed Ethernet Extender from the DIN rail.
Connecting to Power Redundant DC Terminal Block Power Inputs or 12VDC DC Jack: 12VDC DC Jack Step 1: Connect the supplied AC to DC power adapter to the receptacle on the topside of the Hardened Managed Ethernet Extender. Step 2: Connect the power cord to the AC to DC power adapter and attach the plug into a standard AC outlet with the appropriate AC voltage. Redundant DC Terminal Block Power Inputs There are two pairs of power inputs can be used to power up this device.
Chapter 2 – Web-Based Browser Management The Hardened Managed Ethernet Extender provides a web-based browser interface for configuring and managing the Hardened Managed Ethernet Extender. This interface allows you to access the Hardened Managed Ethernet Extender using a preferred web browser. This chapter describes how to configure the Hardened Managed Ethernet Extender using its web-based browser interface.
Understanding the Browser Interface The web browser interface provides groups of point-and-select buttons at the left field of the screen for configuring and managing the Hardened Managed Ethernet Extender.
Basic Settings Network Settings 1. IP configuration: Select “IP configuration” drop-down menu to choose “Static” or “DHCP” from the “IP configuration” drop-down list for the Hardened Managed Ethernet Extender to use a static IP or dynamic IP address (the IP address will be automatically assigned by DHCP server over the network). 2. IP address: Select “IP Address” text box and type a new address to change the IP Address. 3. Netmask: Select “Netmask” text box and type a new address to change the Netmask. 4.
Server Name Settings 1. Server name: Select “Server Name” text box. Type a server name if it is blank, or replace the current server name with a new one. 2. Reload: Select “Reload” button to reload previous settings. 3. Submit: Select “Submit” button to apply new settings. 12 Manual Documentation Number: EIRM-EXTEND-1412m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.
NTP Server Settings NTP Settings: 1. NTP status: Select “NTP status” drop-down menu to select “Enable” or “Disable” from the “NTP status” drop-down list to enable or disable NTP. 2. NTP Server: Select “NTP Server” text box to enter URL or IP address of NTP server. 3. Sync Time: Select “Sync Time” button to synchronize system time of Hardened Managed Ethernet Extender with NTP server. 4. Time Zone: Select “Time Zone” drop-down menu to select a different time zone from the “Time Zone” drop-down list. 5.
Lan Settings 1. Auto: Select “Enable” or “Disable” to enable or disable auto negotiation for Ethernet port of the Hardened Managed Ethernet Extender. 2. Speed: Check “100M” or “10M” to set the speed of Ethernet port to 100Mbps or 10Mbps. 3. Duplex: Check “Full” or “Half” to set the duplex mode of Ethernet port to Full Duplex or Half Duplex. 4. Reload: Select “Reload” button to reload previous settings. 5. Submit: Select “Submit” button to apply new settings.
Enable Asymmetric Mode: 1. Asymmetric Mode: Check “Enable” to enable asymmetric mode for Ethernet Extender port of the Hardened Managed Ethernet Extender. 2. Fixed Rate: Select “Fixed Rate” drop-down menu to disable fixed speed rate or select a fixed speed rate for Ethernet Extender port from the “Fixed Rate” dropdown list. Fixed Rate: bps Disable 59M / 31M 52M / 24M 47M / 14M 42M / 8M 35M / 6M 28M / 5M 25M / 2M 22M / 1M 14M / 1M 1M / 1M 3. 4. Reload: Select “Reload” button to reload previous settings.
Max. Speed: bps 50M 40M 30M 25M 20M 15M 10M 5M 3M 1M 3. Fixed Rate: Select “Fixed Rate” drop-down menu to disable fixed speed rate or select a fixed speed rate for Ethernet Extender port from the “Fixed Rate” dropdown list. Fixed Rate: bps Disable 50M 40M 30M 25M 20M 15M 10M 5M 3M 1M 4. Reload: Select “Reload” button to reload previous settings. 5. Submit: Select “Submit” button to apply new settings.
SNMP Settings 1. Get community: Select the “Get community” textbox and specify a get community name. 2. Set community: Select the “Set Community” textbox and specify a set community name. 3. sysContact: Select the “sysContact” textbox and specify a new contact for SNMP. 4. sysLocation: Select the “sysLocation” textbox and specify a new location for SNMP. 5. sysDescr: Select the “sysDescr” textbox and specify a new description for SNMP. 6.
Link-Fault-Pass-Through Settings 1. Link-Fault-Pass-Through: Check “Enable” or “Disable” to enable or disable linkfault-pass-through for the Hardened Managed Ethernet Extender. 2. Reload: Select “Reload” button to reload previous settings. 3. Submit: Select “Submit” button to apply new settings. Log Settings 1. Event Log: Check or uncheck “Enable” to enable or disable Event Log Setting for the Hardened Managed Ethernet Extender. 2.
Save Configuration 1. Submit: Select “Submit” button to save configuration. Change Password 1. Old password: Select “Old password” text box and type in the old password. 2. New password: Select “New password” text box and type in the new password. 3. Confirm password: Select “Confirm password” text box. Type the same password in “New password” text box again to verify it. 4. Submit: Select “Submit” button to apply new settings.
Accessible List 1. Only packets with following enabled source IP/MAC will be responded: Check this option to enable the following accessible source IP/MAC list. Uncheck this option will allow all source IP/MAC’s connection request. 2. IP1 ~ 8: Select “IP1 ~ 8” text box and specify IP addresses that can access to the Ethernet port on the Hardened Managed Ethernet Extender. Check “Enable” option to enable the IP addresses. 3.
Firmware Upgrade 1. Filename: Select “Filename” text box and type the name of the file that you intend to upgrade it to the Hardened Managed Ethernet Extender. 2. TFTP server IP: Select the “TFTP server IP” textbox and specify the IP address of TFTP server. 3. Submit: Select “Submit” button to apply new settings. Reset VDSL 1. Submit: Select “Submit” button to re-negotiate Ethernet Extender port.
Retrain VDSL 1. Submit: Select “Submit” button to attempt a higher link speed for the Ethernet Extender port. For example, the current link speed of Ethernet Extender port is at 25Mbps. The user can select the “Submit” button which will allow the Ethernet Extender port attempt a link at 30Mbps. 22 Manual Documentation Number: EIRM-EXTEND-1412m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.
System Monitoring System Log 1. Reload: Select the “Reload” button to reload the system log of the Hardened Managed Ethernet Extender. 2. Reset / Clear: Select “Reset / Clear” button to reset and clean the system log of the Hardened Managed Ethernet Extender. Manual Documentation Number: EIRM-EXTEND-1412m 23 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.
VDSL Status 1. Reload: Select the “Reload” button to reload the VDSL status of the Hardened Managed Ethernet Extender. 2. Reset / Clear: Select “Reset / Clear” button to reset and clean the VDSL status of the Hardened Managed Ethernet Extender. Restart Restart System 1. Submit: Select “Submit” button to restart the Hardened Managed Ethernet Extender.
Chapter 3 – Command Line Console Management The Hardened Managed Ethernet Extender provides a command line console interface for configuration purposes. The Hardened Managed Ethernet Extender can be configured either locally through its RS-232 port or remotely via a Telnet session. For the later, you must specify an IP address for the switch first. This chapter describes how to configure the Hardened Managed Ethernet Extender using its console by Commend Line.
The basic commands in the Command Line Interface (CLI) are listed in the following table. System Management Command sys uptime sys date sys date –s MMDDhhmmYYYY.
sys actl add mac MAC sys actl add ip IP sys actl del mac index sys actl del ip index sys actl del mac all sys actl del ip all sys actl enable mac index sys actl enable ip index sys actl disable mac index sys actl disable ip index sys reboot sys reset level1 sys reset level2 sys reset level3 sys ntp sys ntp on sys ntp off sys ntp server IP sys ntp zone time_zone time_zone: +12.0 ~ -12.
sys upgrade IP filename sys lfpt sys lfpt on sys lfpt off Upgrade system with new firmware from a TFTP server. Display Link Fault Pass Through settings. Set Link Fault Pass Through ON. Set Link Fault Pass Through OFF. The basic commands in the Command Line Interface (CLI) are listed in the following table. 28 Manual Documentation Number: EIRM-EXTEND-1412m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.
System Management Command sys uptime sys date sys date –s MMDDhhmmYYYY.
sys actl del mac index sys actl del ip index sys actl del mac all sys actl del ip all sys actl enable mac index sys actl enable ip index sys actl disable mac index sys actl disable ip index sys reboot sys reset level1 sys reset level2 sys reset level3 sys ntp sys ntp on sys ntp off sys ntp server IP sys ntp zone time_zone time_zone: +12.0 ~ -12.
sys lfpt on sys lfpt off settings. Set Link Fault Pass Through ON. Set Link Fault Pass Through OFF. Manual Documentation Number: EIRM-EXTEND-1412m 31 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.
Ethernet Extender Management Command vdsl status vdsl counter vdsl disp vdsl reset chip vdsl reset counter vdsl au vdsl au disp vdsl au level number number: 0 ~ 9 vdsl fixedrate level_number level_number: -1 ~ 9 vdsl retrain vdsl asym-mode on vdsl asym-mode off 32 Command Description Display link performance of Ethernet Extender port. Display statistic counter of Ethernet Extender port. Display settings of Ethernet Extender port. Reset chip of Ethernet Extender port.
Network Management Command net ifconfig net ifconfig disp net ifconfig ip IP IP: IP address of the device net ifconfig netmask IP IP: netmask address for the device net ifconfig up net ifconfig down net ping IP IP: IP address net arp net gateway net gateway disp net gateway add IP IP: gateway address net gateway del IP IP: gateway address net dns net dns disp net dns add IP IP: DNS address net dns del IP IP: DNS address net dhcp net dhcp disp net dhcp on net dhcp off net dhcp renew net an net an disp net an
NET-SNMP Object Model Name Type Value Setting modeName serialNumber versionHW versionSW String(R/W) String(R/W) String(R/W) String(R/W) String String String String sysContact sysDescr sysLocation machineName Dhcp Ntp ntpServer timezone gmtOffset ntpPollingInterval ac(Access Control) Checked acIP0~acIP7 Checked IP acMAC0~acMAC7 Checked MAC communityGet communitySet serverTrap serverTrap0 serverTrap1 serverTrap2 serverTrap3 Log String(R/W) String(R/W) String(R/W) String(R/W) String(R/W) String(R/W) St
ResetVDSL Integer(R/W) “0” or “1” ResetVDSLCounter Integer(R/W) “0” or “1” LinkPerformance TimeConnect Integer(R) SnrBand1 Integer(R) SnrBand2 Integer(R) ERRS Integer(R) FailCnt Integer(R) LFrLosCnt Integer(R) SOTO Integer(R) SORO Integer(R) BCAST Integer(R) RXPAUS Integer(R) TXPAUS Integer(R) TXBCNT Integer(R) RXBCNT Integer(R) LFPT String(R/W) level Reset VDSL chip Reset VDSL counter VDSLStatus SNR of 1st Upstream Band SNR of 2st Upstream Band Uncorrectable code words D
Specifications Applicable Standards IEEE802.3 10Base-T, IEEE802.
EMI EMS Environmental Test Compliance FCC Part 15, Class A VCCI, Class A EN61000-6-4: EN55022, EN61000-3-2, EN61000-3-3 EN61000-6-2: EN61000-4-2 (ESD Standard) EN61000-4-3 (Radiated RFI Standards) EN61000-4-4 (Burst Standards) EN61000-4-5 (Surge Standards) EN61000-4-6 (Induced RFI Standards) EN61000-4-8 (Magnetic Field Standards) IEC60068-2-6 Fc (Vibration Resistance) IEC60068-2-27 Ea (Shock) IEC60068-2-32 Ed (Free Fall) NEMA TS1/2 Environmental requirements for traffic control equipment Manual Docume
NET-SNMP Object Model Name Type Value Setting modeName serialNumber versionHW versionSW String(R/W) String(R/W) String(R/W) String(R/W) String String String String sysContact sysDescr sysLocation machineName Dhcp Ntp ntpServer timezone gmtOffset ntpPollingInterval ac(Access Control) Checked acIP0~acIP7 Checked IP acMAC0~acMAC7 Checked MAC communityGet communitySet serverTrap serverTrap0 serverTrap1 serverTrap2 serverTrap3 Log String(R/W) String(R/W) String(R/W) String(R/W) String(R/W) String(R/W) St
UpgradeLevel Integer(R/W) “0” or “1” ResetVDSL Integer(R/W) “0” or “1” ResetVDSLCounter Integer(R/W) “0” or “1” LinkPerformance TimeConnect Integer(R) SnrBand1 Integer(R) SnrBand2 Integer(R) ERRS Integer(R) FailCnt Integer(R) LFrLosCnt Integer(R) SOTO Integer(R) SORO Integer(R) BCAST Integer(R) RXPAUS Integer(R) TXPAUS Integer(R) TXBCNT Integer(R) RXBCNT Integer(R) LFPT String(R/W) Max.
40 Manual Documentation Number: EIRM-EXTEND-1412m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.