User manual

Manual Documentation Number: EIR618-2SFP-T_4812m 53
B&B Electronics Mfg Co Inc 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 www.bb-elec.com
B&B Electronics Westlink Commercial Park Oranmore, Galway, Ireland Ph +353 91-792444 Fax +353 91-792445 www.bb-europe.com
8021x system nasid
[words]
G
Use the 802.1x system
nasid global
configuration
command to change
the NAS ID
switch(config)# 8021x system
nasid test1
8021x misc quietperiod
[sec.]
G
Use the 802.1x misc
quiet period global
configuration
command to specify
the quiet period value
of the switch.
switch(config)# 8021x misc
quietperiod 10
8021x misc txperiod
[sec.]
G
Use the 802.1x misc
TX period global
configuration
command to set the
TX period.
switch(config)# 8021x misc
txperiod 5
8021x misc
supportimeout [sec.]
G
Use the 802.1x misc
supp timeout global
configuration
command to set the
supplicant timeout.
switch(config)# 8021x misc
supportimeout 20
8021x misc
servertimeout [sec.]
G
Use the 802.1x misc
server timeout global
configuration
command to set the
server timeout.
switch(config)#8021x misc
servertimeout 20
8021x misc maxrequest
[number]
G
Use the 802.1x misc
max request global
configuration
command to set the
MAX requests.
switch(config)# 8021x misc
maxrequest 3
8021x misc
reauthperiod [sec.]
G
Use the 802.1x misc
reauth period global
switch(config)# 8021x misc
reauthperiod 3000