Specifications

Page 3
Document# 430-00137-03 © Copyright 2003-2006, Bioscrypt Inc. All rights reserved.
The two V-Smart modules (fingerprint verification and smart card interface)
must be connected behind the wall plate. Once the cables are connected,
the wall plate may be mounted to the wall.
The V-Smart modules shall have two tabs that slide into slots on the wall plate.
Each module shall be secured to the wall plate by a single #4-40 inch screw.
3.7. Mounting Position
The V-Smart should be mounted on the wall or structure to be in compliance
with all American Disabilities Act (ADA), local and federal laws as they apply
to the installation. The reader should also be mounted at a height that is
comfortable to use. In general, the reader is mounted such that the height of
the sensor (top of the device) is between 48 and 54 inches from the ground.
Should the reader be installed below this mounting height (i.e. on a turnstile),
installation of a wedge piece shall be required between the mounting
surface and the V-Smart wall mounting plate. Please contact Bioscrypt
Technical Support for further information.
Furthermore, the reader will require free space above the reader such that
the user has room to place their finger on the sensor. Roughly, 2-3 inches (or
more) of free space is recommended depending on if there is any
obstruction interfering with the view of the V-Smart. The reader should also be
provided with free space (roughly 3-4 inches recommended) below the
device for convenient access to the bottom RJ11 RS-232 port (see Section
7.3: RS-232 RJ11 Port for further details).
If connecting an external card reader to the V-Smart for enrollment purposes,
the two devices should be placed in close proximity to one another to make
it simple for the enrollment administrator to first present the card at the
external card reader and then prompt the user to place their finger on the
sensor for enrollment. Please see Section 8.3: External Wiegand Reader for
further information.