Specifications
Page 16
Document# 430-00137-03 © Copyright 2003-2006, Bioscrypt Inc. All rights reserved.
Refer to Section 9.6: Fingerprint Placement: Lock, Drop & Hold for further
details.
If no such connection is provided, Bioscrypt will consider that the reader was
not properly installed and may consider the warranty void.
8.3. External Wiegand Reader
The V-Smart reader shall include an embedded Gemplus MIFARE contactless
smart card reader. The V-Smart shall NOT have the ability to read proximity
Wiegand sequences directly. The V-Smart by default shall generate a
Wiegand output sequence based on the fingerprint template ID number. If
using dual-technology contactless smart cards (such as HID 1431 Smart + Prox
cards), the designated V-Smart enrollment station may optionally capture the
Wiegand sequence as provided by the proximity portion of the card by
means of an external proximity card reader. Once captured, the sequence
may be written to the smart card along with the enrolled fingerprint template
where the two items are linked together. When the dual-technology cards
are used in this fashion, V-Smart readers used for access control shall simply
send the Wiegand sequence from the smart card to the Access Control
System. In this case, the Wiegand output sent by V-Smart shall be identical to
the Wiegand output sent by the proximity card reader when the same card is
presented to both devices. Any V-Smart readers used for access control shall
NOT require the connection to the external card reader.
To enroll cards in this manner, a direct connection shall be required from the
proximity card reader to the Wiegand input lines of the V-Smart reader that
has been designated as the enrollment station using the following three
conductors:
Wiegand In Data 0 (Pin 2) connected to the card reader Data 0
Wiegand In Data 1 (Pin 4) connected to the card reader Data 1
Wiegand GND (Pin 6) connected to the card reader Power GND*
An 18 – 22 AWG cable should be used for this connection. The V-Smart reader
by default shall have the Wiegand input activated for Standard 26-bit
Wiegand format. The reader shall support other formats. Refer to Appendix B:
Wiegand Protocol for further information.
*Wiegand GND (Pin 6) should be commoned to both Power GND on the
external Wiegand reader and the Access Control System reader Power GND
if Wiegand output is also used (refer to Section 8.4: Access Control System).