User guide

International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
orders@bb-elec.com
support@bb-elec.com
Heavy Industrial RS-232 to
RS-422/485 Isolated Converter
485DRCI-PH
IEC 61850-3 ELECTRO MAGNETIC INTERFERENCE SPECIFICATIONS
test desCriPtion test level level
61000-4-2 ESD
Enclosure Contact 8 kV 4
Enclosure Air 15 kV 4
61000-4-3 Radiated RFI Enclosure Ports 10 V/m 3
61000-4-4 Burst (Fast Transient)
Signal Ports 4 kV @ 2.5 Khz ------
DC Power Ports 4 kV 4
61000-4-5 Surge
Signal Ports 2 kV line to earth, 1 kV line to line 4
DC Power Ports 2 kV line to earth, 1 kV line to line 3
61000-4-6 Induced (Conductive) RFI
Signal Ports 10 V RMS 3
DC Power Ports 10 V RMS 3
61000-4-12 Damped Oscillatory
Signal Ports 2.5 kV common, 1 kV diff mode @ 1MHz 3
DC Power Ports 2.5 kV common, 1 kV diff mode @ 1MHz 3
61000-4-16 Mains Frequency Voltage
Signal Ports 30 V Continuous, 300 V for 1 s 4
DC Power Ports 30 V Continuous, 300 V for 1 s 4
61000-4-17 Ripple on DC Power Supply DC Power Ports 10% 3
IEEE 1613 C37.90 ELECTROMAGNETIC INTERFERENCE SPECIFICATIONS
test desCriPtion test level level
C37.90.3 ESD
Enclosure Contact 8 kV ------
Enclosure Air 15 kV ------
C37.90.2 Radiated RFI Enclosure Ports 10 v/m ------
C37.90.1 Fast Transient
Signal Ports 4 kV @ 2.5 kHz ------
DC Power Ports 4 kV ------
ENVIRONMENTAL SPECIFICATIONS
test desCriPtion test level level
60068-2-1 Cold Temperature Test Ad (-)40 C, 16 Hours ------
60068-2-2 Dry Heat Test Bd (+)85 C, 16 Hours ------
60068-2-30 Humidity (damp heat cycle) Test Dd 90% (non-condensing) (+)55C, 6 Cycles ------
IEC 60068-2-6 Vibration Test Fc 4G Class 2
IEC 60068-2-27 Shock Test Ea 50G Class 2
IEC 60068-2-32 Drop ------ 6 faces, 3 edges, 1 corner total 10 drops at 1 m ------