User's Manual
Documentation Number 3PCIOSD1x-3903m Manual  Appendix C  C-1 
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Comm. Pk. – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 
Appendix C: Jumper Mode Table 
Jumpers 
Port 1 (A) 
RS-232 RS-422 
4-Wire 
RS-485 
4-Wire 
RS-485 
2-Wire 
JP1 
Control 
RTS(232)  not used  SD/RTS *  SD/RTS * 
JP2 A  232  422/485 422/485 422/485 
JP2 B  232  422/485 422/485 422/485 
JP2 C  232  422/485 422/485 422/485 
JP3 D  232  422/485 422/485 422/485 
JP4 TX  not used  422  485  485 
JP4 RX not used 422 422 485 
JP4 
Termination 
not used IN/OUT IN/OUT IN/OUT 
JP3 
Clock 
*4/*1 *4/*1 *4/*1 *4/*1 
How to Use the Table: The left vertical column shows the jumpers 
for the port. The four right vertical columns show the position setting 
of the jumper at the left for RS-232, RS-422 or 4-wire RS-485 or 2-
wire RS-485 modes. 
NOTES: 
RS-485 Mode: The JP1 Control jumper should be set to Send Data 
mode unless your software requires RTS control. 
Refer to the Setup section for explanations of the SD/RTS, 
Termination and Clock settings. 
Note that termination should only be used in systems with both high 
baud rates (>19200) and over several thousand feet of cable. 
Information on RS-422 and RS-485 communications can be found in 
the B&B Electronics RS-422/485 Application Note (available free 
on our websites). 
C-2  Appendix C  Documentation Number 3PCIOSD13903m Manual 
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Comm. Pk. – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 