User Guide

232XS5-1005 Manual 5
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445
Table 4. DTE MASTER PORT CHART
The 232XS5 supports the following RS-232 signals: TD, RD,
SG, RTS, CTS, DCD, DSR and DTR.
NOTE: All other lines are not connected.
The Smart Switch selects port A as the default port at power up.
Table 3. DCE MASTER PORT CHART
Master Port
(DCE)
Signal
A
,B,C,D & E Port
s
(DTE)
Pin# Direction Description Pin# Direction
3 Input Transmit Data (TD) 3 Output
2 Output Receive Data (RD) 2 Input
7 Input Request to Send (RTS) 7 Output
8 Output Clear to Send (CTS) 8 Input
4 Input Data Terminal Ready (DTR) 4 Output
6 Output Data Set Ready (DSR) 6 Input
1 Output Data Carrier Detect (DCD) 1 Input
5 <-------> Signal Ground (SG) 5 <----->
Master Port
(DTE)
Signal
A
,B,C,D & E Port
s
(DCE)
Pin# Direction Description Pin# Direction
3 Output Transmit Data (TD) 3 Input
2 Input Receive Data (RD) 2 Output
7 Output Request to Send (RTS) 7 Input
8 Input Clear to Send (CTS) 8 Output
4 Output Data Terminal Ready (DTR) 4 Input
6 Input Data Set Ready (DSR) 6 Output
1 Input Data Carrier Detect (DCD) 1 Output
5 <-------> Signal Ground (SG) 5 <----->
232XS5-1005 Manual
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445
6
Serial Data Configuration
In order for the host device that is connected to the master port
to select any of the five ports, the Smart Switch must be set to
match the host's communication format. Dipswitch “SW1” is used to
select the communication format of the Smart Switch. Switch
positions 1 through 3 select the baud rate. Switch position 4 selects
7 or 8 data bits. Switch position 5 determines if parity is enabled or
disabled.
NOTE: A data format of 7 data bits, no parity and one stop is
not allowed.
Switch position 8 selects the port configuration, see section
titled "Port Configuration". Refer to Table 1.
Always
power down
the smart switch when changing switch settings.
RS-485 Support
RS-485 support may be
provided by adding a Model
485SD9TB RS-232 to RS-485
converter or other recommended
device to the slave ports of the
232XS5.
Port power of about 30 mA may be applied through the DTR line
(Pin 4) of the slave ports with jumper JP1-JP5. Normally, the
jumpers are set to allow DTR to pass from the master port. To
enable port power on a slave port, move the jumper from the“OFF”
to “ON” position on the corresponding JP jumper. To allow DTR to
pass from the master port to the slave port, move jumper from “ON”
to “OFF” on the corresponding JP jumper. DTR can only pass
through when the port is selected and the jumper is set to the “OFF”
position on the corresponding slave port JP jumper.
Table 5. Port Power Jumpers
* = FACTORY DEFAULT
Jumper
JP1-5
Setting
“OFF” DTR passed *
“ON” Port Power