Technical data
Alarm Troubleshooting ◆ ProMix™ II Alarms
310633C 51
Alarm Troubleshooting
ProMix™ II Alarms
The ProMix™ II alarms alert you of a problem and help
prevent off-ratio spraying. If an alarm occurs, operation
stops and the following occurs:
• A red LED illuminates steadily or flashes on the
Operator Station.
• Operator Station displays an alarm E-Code (E1-E9).
• Alarm sounds.
• Status bar on the EasyKey™ Display shows the
E-Code with a description.
Alarms E-Codes
To Clear Alarm and Restart
Except for Potlife Exceeded (E3) Alarm and Purge Error
(E2) Alarm, page 52, all alarms can be cleared by press-
ing the Error Clear
key on the Operator Station.
WARNING
Follow Pressure Relief Procedure, page 38, when
you stop spraying, before changing spray tips, and
before cleaning, checking, or servicing equipment.
Read warnings, page 6.
CAUTION
Do not use the fluid in the line that was dispensed off
ratio as it may not cure properly.
Operator Station
E-Code
Red LED
Description E-Code
Communication Error E1
Purge Error E2
Potlife Exceeded Alarm E3
Ratio Alarm E4
Overdose Alarm E5
Dose Time A Alarm E6
Dose Time B Alarm E7
Autodump Complete Alarm E8
EasyKey in Setup Mode E9
When an alarm occurs be sure to determine the
E-Code before clearing it. If you forget which
E-Code occurred, you can use the EasyKey™
Report screen (page 34) to view the last 10 alarms,
with date and time stamps.










