Technical data

Setup Mode Color Screen
310633C 33
ProMix™ II Purge Sequence
ProMix™ II Color Change Sequence
FIG. 35
Legend:
Pa: Air purge valve
Ps: Solvent purge valve
Ps-final: Solvent purge valve (final solvent fill is 25% of purge time)
Pa = Air chop time set in Advance Screen 1, page 35.
Ps = Solvent chop time set in Advance Screen 1, page 35.
PS-final
25% of Purge Time
Gun Trigger
Purge Sequence
Purge Time
Pa Ps Pa Ps Pa Ps Pa
S1
A
C2
A
AB
AB
AB
AB
Legend:
S1: cc stack solvent valve
C2: cc stack color 2 valve
A: Component A dispense valve
B: Component B dispense valve
Pa: Air purge valve
Ps: Solvent purge valve
Ps-final: Solvent purge valve (final solvent fill is 25% of purge
time or 50% of purge time when color changing to 0)
PS-final
Gun Trigger
Purge Sequence
Purge Time
Pa Ps Pa Ps Pa Ps Pa
Mix
Fill Time
5 second
load cc
stack
5 second
flush cc
stack
Pa = Air chop time set in Advance Screen 1, page 35.
Ps = Solvent chop time set in Advance Screen 1, page 35.