Technical data

Operator Controls Operator Station
310633C 27
* If a potlife alarm (code E3) occurs, you must purge the system with solvent or spray new mixed material before
the alarm can be fully cleared.
F
IG. 27
For additional information about alarms, see Alarm Troubleshooting, page 51.
The number of colors available when scrolling with the
or keys is determined during software setup.
See page 32.
Color 0 can be selected to purge the system (as an alternative to Purge key) on multiple color units.
Refer to page 32.
Color change and alarm indicator
Normally displays color number.
If an alarm occurs, displays an alarm code,
E1 to E9.
Color number displays after alarm is cleared.
Color change sequence indicator (green LED)
Stays lit while a color is in use.
Shuts off when or keys are pressed.
If a new color is entered, the LED blinks while the color is loaded
and turns solid after loading is complete.
A new color is selected by pressing or then pressing .
Error Clear
Red LED stays lit
when error occurs
or blinks for a potlife
alarm
LED shuts off after
alarm is cleared &
key is pushed.*
Report
Sends report to
printer and resets A
and B totalizers.
Green LED blinks
once after key is
pressed.
Mix
Starts Mix mode.
Green LED remains
lit while in Mix
mode.
LED blinks when 2
minute idle time is
exceeded.
Up
Scrolls color numbers
up.
Down
Scrolls color numbers
down.
Enter
Enters selected color
and starts color
change sequence.
Standby
Starts Standby mode.
Green LED remains lit
while in Standby mode.
Purge
Starts Purge mode.
Green LED blinks during purge
sequence and turns solid once purge is
complete. LED turns off when another
mode is started.